![Amada ML-2550A Скачать руководство пользователя страница 162](http://html1.mh-extra.com/html/amada/ml-2550a/ml-2550a_operation-manual_2915851162.webp)
162
ML-2550A/2551A
4. Commands
* When the external input/output control is turned OFF at "1: Control by
external input/output signals (Output schedules are set on the laser
controller)", the control method is changed to "0: Control by laser controller."
* When the external input/output control is turned OFF at "5: Control by
external input/output signals (Output schedules are set on the personal
computer)", the control method is changed to "2: Control by external
communication control."
s1
HV (high voltage) (0: OFF 1: ON □: Current status kept)
s2
LD (guide light) (0: OFF 1: ON □: Current status kept)
s3
Resonator shutter (0: OFF 1: ON □: Current status kept)
s4
Branch shutter 1 (0: OFF 1: ON □: Current status kept)
s5
Branch shutter 2 (0: OFF 1: ON □: Current status kept)
s6
Branch shutter 3 (0: OFF 1: ON □: Current status kept)
s7
Branch shutter 4 (0: OFF 1: ON □: Current status kept)
s8
Unused (fixed to □)
s9
Unused (fixed to □)
mon
Automatic laser power monitor value transmission (0: OFF 1: ON □: Current
status kept)
Each time the flashlamp comes on, "00 Laser Power Monitor-Energy, number
of waveform data, etc." on page 159 is sent. In the case of a high-speed
repeated output, however, the data is sent at certain intervals because the
communication is too quick.
Even if the control method is changed in "cnt", the data is sent automatically
until the power supply is turned OFF.
ACK or NAK
Valid only at external communication control. If there is any setting that
cannot be changed, all are invalidated and [NAK] is returned.
Setting the Mirror of the Timesharing Unit
The command (code: WM) to set the mirror of the timesharing unit is explained below.
CH1/CH0
Equipment No. (CH1 = tens digit, CH0 = units digit)
m1
Timesharing unit 1 (0: OFF 1: ON □: Current status kept)
m2
Timesharing unit 2 (0: OFF 1: ON □: Current status kept)
m3
Timesharing unit 3 (0: OFF 1: ON □: Current status kept)
m4
Unused (fixed to □)
m5
Unused (fixed to □)
Содержание ML-2550A
Страница 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 116: ......
Страница 144: ......
Страница 168: ......
Страница 173: ...Maintenance Part...
Страница 174: ......
Страница 203: ...Appendixes...
Страница 204: ......