MD Series
9. External Communication Function
9-5
(3) Single-Directional Communication C Mode
(COMMUNICATION MODE on STATUS Screen is C MODE)
1
1-step welding (When SCHEDULE MODE on the STATUS screen is set to SINGLE)
Data strings: M: 01, 01, 001212, kA, W1, 5.00, 4.50, 4.50, 4.00, 18.0, 0.89, 2.00, P, 1.00,
A B
C D
E F G H I J K L M N
O
0.50, 1.00 [CR][LF]
P Q R
Ex.) M: 01,01,001212,kA,W1,5.00,4.50,4.50,4.00,18.0,0.89,2.00,P,1.00,0.50,1.00[CR][LF]
Item
Character
string
Content Range
A
M:
Monitor value sending code
M: (fixed)
B
**,
Device No.
01 to 31
C
**,
Schedule No.
01 to 31
D
******,
Counter
000000 to 999999
E **,
Unit of current value
kA: Current value in kA
kA
F
W1,
Welding code (1-step welding)
W1 (fixed)
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
G
****,
*3
Peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
H
****,
*3
WELD: Current
Average value
0000 to 0999[kA] ,----
*6
I
*.**,
Peak value
0.00 to 9.99[V] ,----
*6
J *.**,
WELD: Voltage
Average value
0.00 to 9.99[V] ,----
*6
**.*,
*1
00.0 to 99.9[kW] ,----
*6
K
****,
*2*3
WELD: Power average value
0000 to 0999[kW] ,----
*6
L
*.**,
WELD: Resistance average value
0.00 to 9.99[m
Ω
] ,----
*6
*.**,
*4
0.00 to 9.99[ms]
M
**.*,
*5
WELD: Weld time
(Set time)
00.0 to 99.9[ms]
N
P,
Welding code (Precheck welding)
P (fixed)
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
O
****,
*3
Peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
P
****,
*3
PRECHECK:
Current
Average value
0000 to 0999[kA] ,----
*6
*.**
*4
0.00 to 1.00[ms]
Q
**.*
*5
PRECHECK: Weld time
(Set time)
00.0 to 01.0[ms]
R
[CR][LF]
CR, LF code
0DH 0AH (fixed)
Содержание MD Series