MD Series
6. Explanation of the Screen
6-14
⑭
MONITOR FIRST TIME
Sets the interval not calculating the measured value.
OFF
AVE (average value) measures the interval except upslope and
downslope.
PEAK (peak value) measures the entire interval of weld time.
Upslope and downslope are included in the measurement
interval.
00.0ms
to
99.9ms
AVE (average value) measures the interval except the welding
start to this setting and downslope regardless the upslope
setting.
PEAK (peak value) measures the interval except the welding
start to this setting regardless the upslope/downslope setting.
In most cases, the initial setting should not be changed.
⑮
WELD TIME
Sets the length of weld time.
NORMAL
The setting ranges are W1: 0.00 to 9.99 ms, COOL: 0.00 to
9.99 ms, and W2: 0.00 to 9.99 ms.
LONG
The setting ranges are W1: 00.0 to 99.9 ms, COOL: 00.0 to
49.9 ms, and W2: 00.0 to 99.9 ms. Set the total time of W1, CO
and W2 to 100 ms or less.
Time period for which a welding can be performed
The time period for which a welding can be performed depends on the
setting of current value and the status of load. Check the measured value
and waveform on the MONITOR screen to set the welding. When the
current value and weld time higher than the output capacity of the
equipment are set, the power is reduced during welding.
⑯
POLARITY CHANGE (MD-B5000A only)
Selects the current direction of both W1 and W2 when 2-step welding is used.
ON
Opposite
direction
W1 W2
OFF
Same
direction
⑰
PREV
Moves to the STATUS (1/2) screen.
⑱
COMM
Moves to the COMMUNICATION SETTING screen.
⑲
ERROR
Moves to the ERROR SETTING screen.