MD Series
9. External Communication Function
9-19
7) Specified code No.: S06 (PRECHECK screen)
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S06[CR][LF]
MD series -> Host PC
!01008S06: 1, 1.00, 0.50, kA, 2.20, 1.80, 1.20, 0.80 [CR][LF]
A
B C D
E F G H
Item
Character
string
Content Range
Increment/
Decrement
A *,
0: Precheck welding OFF
1: Precheck welding ON
0 to 1
1
*.**,
*1
0.00 to 1.00[ms]
0.01
B
**.*,
*2
RC: Time
00.0 to 01.0[ms]
0.1
C
*.**,
RC: Voltage
0.00 to 9.99[V]
0.01
D **,
Unit of current value
kA: Current value in kA
kA -
*.**,
*3
0.00 to 9.99[kA]
0.01
**.*,
*4
00.0 to 99.9[kA]
0.1
E
****,
*5
RC: Current peak value upper
limit
0000 to 0999[kA] 1
*.**,
*3
0.00 to 9.99[kA]
0.01
**.*,
*4
00.0 to 99.9[kA]
0.1
F
****,
*5
RC: Current peak value lower
limit
0000 to 0999[kA] 1
*.**,
*3
0.00 to 9.99[kA]
0.01
**.*,
*4
00.0 to 99.9[kA]
0.1
G
****,
*5
RC: Current average value upper
limit
0000 to 0999[kA] 1
*.**
*3
0.00 to 9.99[kA]
0.01
**.*
*4
00.0 to 99.9[kA]
0.1
H
****
*5
RC: Current average value lower
limit
0000 to 0999[kA] 1
*1: When WELD TIME on the STATUS screen is NORMAL.
*2: When WELD TIME on the STATUS screen is LONG.
*3: When CURRENT RANGE on the STATUS screen is *.**kA.
*4: When CURRENT RANGE on the STATUS screen is **.*kA.
*5: When CURRENT RANGE on the STATUS screen is ***kA.
Содержание MD Series
Страница 111: ......