MD Series
9. External Communication Function
9-7
2
2-step welding
(When SCHEDULE MODE on the STATUS screen is set to DOUBLE)
Data strings: M: 01, 01, 001212, kA, W1, 5.00, 4.50, 4.50, 4.00, 18.0, 0.89, 2.00,
A B
C D
E F G H I J K L M
W2, 5.00, 4.50, 4.50, 4.00, 18.0, 0.89, 2.00, P, 1.00, 0.50, 1.00 [CR][LF]
N O P Q R S T U V W X Y Z
Ex.) M: 01,01,001212,kA,W1,5.00,4.50,4.50,4.00,18.0,0.89,2.00,W2,5.00,4.50,4.50,4.00,
18.0,0.89,2.00,P,1.00,0.50,1.00[CR][LF]
Item
Character
string
Content Range
A
M:
Monitor value sending code
M: (fixed)
B
**,
Device No.
01 to 31
C
**,
Schedule No.
01 to 31
D
******,
Counter
000000 to 999999
E **,
Unit of current value
kA: Current value in kA
kA
F
W1,
Welding code (1-step welding)
W1 (fixed)
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
G
****,
*3
Peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
H
****,
*3
W1: Weld 1
Average value
0000 to 0999[kA] ,----
*6
I
*.**,
Peak value
0.00 to 9.99[V] ,----
*6
J *.**,
W1: Voltage 1
Average value
0.00 to 9.99[V] ,----
*6
**.*,
*1
00.0 to 99.9[kW] ,----
*6
K
****,
*2*3
W1: Power 1 average value
0000 to 0999[kW] ,----
*6
L
*.**,
W1: Resistance 1 average value
0.00 to 9.99[m
Ω
] ,----
*6
*.**,
*4
0.00 to 9.99[ms]
M
**.*,
*5
W1: Weld 1 time
(Set time)
00.0 to 99.9[ms]
N
W2,
Welding code (2-step welding)
W2 (fixed)
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
O
****,
*3
Peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.9[kA] ,----
*6
P
****,
*3
W2: Weld 2
Average value
0000 to 0999[kA] ,----
*6
Q
*.**,
Peak value
0.00 to 9.99[V] ,----
*6
R *.**,
W2: Voltage 2
Average value
0.00 to 9.99[V] ,----
*6
**.*,
*1
00.0 to 99.9[kW]
,
----
*
6
S
****,
*2*3
W2: Power 2 average value
0000 to 0999[kW]
,
----
*
6
T
*.**,
W2: Resistance 2 average value
0.00 to 9.99[m
Ω
]
,
----
*
6