MD Series
5. Connection
5-21
When the start signal is input while the MONITOR screen is displayed, the
screen display is canceled to accept the next start. The next start is
accepted 5 ms after end output and communication output are complete.
When the screen display is canceled to accept the start, the start stability
time is [START SIG. TIME s 5 ms maximum].
Start-waiting time
Time duration required to turn off the start input after end output,
communication output, and screen display are all complete.
Start-waiting time: 5 ms
Also, the status does not change until the start-waiting time goes by even if
the input signal such as schedule select, polarity-switching select, etc. is
changed.
・
When a fault and caution occur during welding
*1: For the timing of the end signal, refer to
1
MD-A series
and
2
MD-B
series
.
Communication output time
Communication output of monitor value. Outputs after the start of end
output.
When COMMUNICATION MODE on the STATUS screen is B MODE
9600 bps of communication speed: 110 ms max.
19200 bps of communication speed: 59 ms max.
38400 bps of communication speed: 32 ms max.
When COMMUNICATION MODE on the STATUS screen is C MODE
9600 bps of communication speed: 161 ms max.
19200 bps of communication speed: 85 ms max.
38400 bps of communication speed: 45 ms max.
(END)
(NG,CAUTION)
*1
Start input
Welding current
Comunication output time
Screen display time
Fault reset waiting time
End output
Fault/Caution output
(2ND)