MD Series
9. External Communication Function
9-15
*1: When WELD TIME on the STATUS screen is NORMAL.
*2: When WELD TIME on the STATUS screen is LONG.
*3: When CURRENT RANGE on the STATUS screen is *.**kA.
*4: When CURRENT RANGE on the STATUS screen is **.*kA.
*5: When CURRENT RANGE on the STATUS screen is ***kA.
*6: Range depends on CURRENT RANGE on the STATUS screen.
4) Specified code No.: S03 (MONITOR screen)
Data strings: When reading Device No. 01 (Set 000 for Schedule No.)
Host PC -> MD series
#01R000S03[CR][LF]
MD series -> Host PC
!01000S03: 1, 1, 0, 0, 1, 1 [CR][LF]
A B C D E F
Item
Character
string
Content Range
Increment/
Decrement
A *,
Display of current monitor value
0: Hide
1: Display
0 to 1
1
B *,
Display of voltage monitor value
0: Hide
1: Display
0 to 1
1
C *,
Display of power monitor value
0: Hide
1: Display
0 to 1
1
D *,
Display of resistance monitor
value
0: Hide
1: Display
0 to 1
1
E *,
Displayed item of current monitor
value
0: Average value
1: Peak value
0 to 1
1
F *
Displayed item of voltage monitor
value
0: Average value
1: Peak value
0 to 1
1