MD Series
10. Specifications
10-1
10.
Specifications
(1) Product Specifications
(Items in can be set for each schedule.)
Power supply
Single-phase, 100 V AC-10% to 120 V AC +10% or 200 V AC-10% to
240 V AC +10% (50/60 Hz)
The voltage is cannot be selected. (Fixed on shipment.)
Control method
Switching control by transistor
The basic frequency is 125 kHz, and the frequency is 1/integer of it.
Maximum is 125 kHz (frequency is variable automatically).
Welding current
control
Constant-current
control method
Controls so that the welding current will be the
set current.
Constant-voltage
control method
Controls so that the voltage detected by the V
SENS cable attached between electrodes will be
the set voltage.
Combination control
of constant-current
and constant-voltage
The constant-voltage control method and the
constant-current-control method function
simultaneously, and priority is given to the
control method whichever reaches the set value.
Timer setting
1-step weld sequence
a. Squeeze
: 0000–9999 ms
b. Precheck weld
: 0.00–1.00 ms
*1
c. Precheck judgment : 2 ms (fixed)
*1
d. Upslope
: 0.00–9.99 ms [00.0–99.9 ms]
*2
e. Weld
: 0.00–9.99 ms [00.0–99.9 ms]
f. Downslope
: 0.00–9.99 ms [00.0–99.9 ms]
*2
g. Hold
: 000–999 ms
2-step weld sequence
a. Squeeze
: 0000–9999 ms
b. Precheck weld
: 0.00–1.00 ms
*1
c. Precheck judgment : 2 ms (fixed)
*1
d. Upslope 1
: 0.00–9.99 ms [00.0–99.9 ms]
*3
e. Weld 1
: 0.00–9.99 ms [00.0–99.9 ms]
f. Downslope 1
: 0.00–9.99 ms [00.0–99.9 ms]
*3
g. Cool
: 0.00–9.99 ms [00.0–49.9 ms]
h. Upslope 2
: 0.00–9.99 ms [00.0–99.9 ms]
*4
i. Weld 2
: 0.00–9.99 ms [00.0–99.9 ms]
j. Downslope 2
: 0.00–9.99 ms [00.0–99.9 ms]
*4
k. Hold
: 000–999 ms
Set the total time of Weld 1, Cool and Weld 2 to 100 ms or less.
*1
This item is not shown on the SCHEDULE screen. A dedicated setting screen is used
for setting. The set value is ignored when the precheck function is set to OFF.
*2
Included in weld time.
*3
Included in weld 1 time.
*4
Included in weld 2 time.