MD Series
9. External Communication Function
9-26
12) Specified code No.: S12 (Monitor value output)
Used when SCHEDULE MODE on the STATUS screen is DOUBLE.
In case of SINGLE, use Specified code No. S11.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S12[CR][LF]
MD series -> Host PC
!01008S12: 001212, kA, 2.00, 1.86, 3.20, 2.61, 04.9, 1.40, 1.00, 3.02, 2.73,
A
B C D E F G H I J K
4.32, 3.87, 10.6, 1.42, 1.00, 1.43, 0.75, 1.00 [CR][LF]
L M
N O
P Q
R S
Item
Character
string
Content Range
A
******,
Counter
000000 to 999999
B **,
Unit of current value
kA: Current value in kA
kA
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.0[kA] ,----
*6
C
****,
*3
W1: Current 1 peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.0[kA] ,----
*6
D
****,
*3
W1: Current 1 average value
0000 to 0999[kA] ,----
*6
E
*.**,
W1: Voltage 1 peak value
0.00 to 9.99[V] ,----
*6
F
*.**,
W1: Voltage 1 average value
0.00 to 9.99[V] ,----
*6
**.*,
*1
00.0 to 99.9[kW] ,----
*6
G
****,
*2*3
W1: Power 1 average value
0000 to 0999[kW] ,----
*6
H
*.**,
W1: Resistance 1 average value
0.00 to 9.99[m
Ω
] ,----
*6
*.**,
*4
0.00 to 9.99[ms]
I
**.*,
*5
W1: Weld 1 time
(Set time)
00.0 to 99.9[ms]
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.0[kA] ,----
*6
J
****,
*3
W2: Current 2 peak value
0000 to 0999[kA] ,----
*6
*.**,
*1
0.00 to 9.99[kA] ,----
*6
**.*,
*2
00.0 to 99.0[kA] ,----
*6
K
****,
*3
W2: Current 2 average value
0000 to 0999[kA] ,----
*6
L
*.**,
W2: Voltage 2 peak value
0.00 to 9.99[V] ,----
*6
M
*.**,
W2: Voltage 2 average value
0.00 to 9.99[V] ,----
*6
**.*,
*1
00.0 to 99.9[kW] ,----
*6
N
****,
*2*3
W2: Power 2 average value
0000 to 0999[kW] ,----
*6
O
*.**,
W2: Resistance 2 average value
0.00 to 9.99[m
Ω
] ,----
*6
Содержание MD Series