MD Series
7. Basic Operation
7-3
9
Select SCHEDULE and press the ENTER key.
Move to the welding test. Perform the actual welding and check to see if the welding
schedule is set correctly.
Press the MENU key and return to the menu screen.
Next, select COMPARATOR, and press the ENTER key to go to the COMPARATOR
screen.
⑪
Press the WELD key on the front panel to turn the WELD lamp on.
⑫
Turn on (close) the WE ON/OFF of the I/O connector on the front panel.
Check that the READY lamp on the front panel is on.
The READY lamp comes on when the WELD lamp on the front panel comes on
and Pin 8 (WE ON/OFF) of the I/O connector on the front panel are closed.
It goes out when a fault occurs, welding, or charging.
⑬
Input the schedule-select signal.
Turn on (close) SCH1/SCH2/SCH4/SCH8/SCH16 (as well as PARITY) of the I/O
connector on the front panel to select schedule No.15.
⑭
Turn on (close) the 2ND start input to start welding.
The welding starts when the weld force signal is output and the welding head begins
to apply weld force.
Record the monitor values shown at this time.
You can check that each device is performing welding by the illumination of the
WELD STAR lamp on the slave.
Record these values.
→
Set the schedule No. to 15.
. Set the current and voltage.
. Set the weld time.
Содержание MD Series