MD Series
6. Explanation of the Screen
6-4
(a)
(c)
(d) (h) (e) (i) (f) (g)
(a)
(c)
(d) (h) (e) (i) (f) (g)
(3) Displaying the Measured Value (MONITOR Screen)
Displays the measured value of current, voltage, power, and resistance at
welding.
Current is indicated in yellow solid line, Voltage is cyan, Power is green, and
Resistance is magenta.
Move the cursor ( ) to function key ((d) to (g)) to be selected and press the
ENTER key to display the desired screen. Press one more time the ENTER key
to erase the displayed data.
Average value (AVE) and peak value (PEAK) of measured current and voltage
can be switched by pressing the ENTER key after selecting the function key ((h),
(i)).
Note) Waveform and measured value hold the latest data of each schedule.
When the power is turned off, all values are cleared.
[When displaying data of two or less] [When displaying data of three or more]
(a) SCH.#
Denotes No. of SCHEDULE (welding condition).
Input the schedule number that you want to check the waveform and
measured value. After welding, the number is switched to the schedule
number of the welding.
(b) Waveform
Displays the measured waveform of the item selected among current, voltage,
power and resistance.
(c) Measured value
Displays the average and peal values of the item selected among current,
voltage, power and resistance, and count of the welding judged good.
(b)
Содержание MD Series