CHAPTER 5: MAINTENANCE
IS-300CA INVERTER POWER SUPPLY
990-
418
5-5
FAULT
CODE
CONTENTS
CAUSE
MEASURES
E-37
OUT LIMIT OF
DISPLACEME
NT ERROR
IS-300CA
Advanced
ONLY: The
displacement
is out of
the
DISPLACEMENT LIMIT setting range
on the DISPLACEMENT screen.
Check work pieces, welder and welding
power supply voltage.
Check range set at DISPLACEMENT
LIMIT.
E-38
WORK
DETECTERRO
R
IS-300CA
Advanced
ONLY:
The
workpiece detection is out of the WORK
DETECT LIMIT setting range on the
DISPLACEMENT screen.
Check work piece setting and positioning.
Check range set at WORK DETECT LIMIT.
E-39
WITHOUT
EXTENSION
BOARD
IS-300CA
Advanced
ONLY:
The
optional extended board is not connected.
Recycle power. If the E-39 WITHOUT
EXTENSION BOARD is displayed again,
repair is required.
Contact Amada Weld Tech
When the Welding Does not Start
,
Even if the Start Signal is Input
When welding does not start, even if the Start signal
2ND STAGE
signal is present, verify the following:
•
READY indicator is not on.
•
The Start signal is shorter than DELAY START SET time setting.
•
The Start signal is present while the END signal is present.
•
Start signal is present during communications with the Pendant.
Tb
Ta
T
SQD
SQZ
WE1
HOLD
END
(Note 1 )
T : DELAY START SET
(Note 2 )
(Note 3 )
Ta : Data commun icat ion
Tb : Data commun icat ion
t ime at start
t ime at end
CAUT ION
HEAT
Ⅰ
2ND STAGE
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...