APPENDIX E: EtherNet/IP
TM
COMMUNICATIONS
IS-300CR INVERTER POWER SUPPLY
990-418
E-25
These controller tags contain the mask bits to control the IS-300CR digital inputs. The PLC program is
responsible for setting and clearing the bit tag since it doesn’t self-clear like the request flag tags.
For example; to select schedule number 5 via digital inputs, ioControl.do.schdule1DO1_1 and
ioControl.do.schdule4DO3_1 must be set to 1.
ioControl.do.schedule1DO1_1
Digital bit to select schedule 1 masking bit
ioControl.do.schedule2DO2_1
Digital bit to select schedule 2 masking bit
ioControl.do.schedule4DO3_1
Digital bit to select schedule 4 masking bit
ioControl.do.schedule8DO4_1
Digital bit to select schedule 8 masking bit
ioControl.do.schedule16DO5_1
Digital bit to select schedule 16 masking bit
ioControl.do.schedule32DO6_1
Digital bit to select schedule 32 masking bit
ioControl.do.schedule64DO7_1
Digital bit to select schedule 64 masking bit
ioControl.do.schedule128DO8_1
Digital bit to select schedule 128 masking bit
ioControl.do.we1StopParityDO9_1
Digital bit to set the weld 1 stop parity flag
ioControl.do.we2StopWeldCountDO10_1
Digital bit to set the weld 2 Stop Weld Count flag
ioControl.do.stage1DO11_1
Digital bit to set weld head stage 1 control
ioControl.do.stage2DO12_1
Digital bit to set weld head stage 2 control
ioControl.do.weldOnOffDO1_2
Digital bit to set the weld On/Off control flag
ioControl.do.errorResetDO2_2
Digital bit to set the digital error reset request
ioControl.do.stepResetDO3_2
Digital bit to set the step reset flag
ioControl.do.we3StopCountResetDO4_2
Digital bit to set the weld 3 Stop Count Reset flag
ioControl.do.backStepDO5_2
Digital bit to set the back step flag
ioControl.do.stepModeDO6_2
Digital bit to set the step mode flag
ioControl.do.retract1DO7_2
Digital bit to set the retract 1 flag
ioControl.do.retract1DO8_2
Digital bit to set the retract 2 flag
Digital Input Tags
The digital input tags are outputs from IS-300CR Inverter Power Supply. These digital input tags are
read-only and for monitoring the digital output status of the IS-300CR Inverter Power Supply.
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...