APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-14
990-418
IS-300CA Advanced / EtherNet/IP
TM
:
Screen 03 (STEPPER data) Common data (Valve No.: 001
to 004)
Example of data writing:
#01W001S03:1,0000,0,0000,100,0,0000,100,0,0000,100,0,0000,100,0,0000,100,0,0000,100,0,000
0,100,0,0000,100,0,01,0000
[CR][LF]
Item
Contents
Character
String
Range
1
START ON STEP #
n,
1 to 9
2
COUNT of STEP1
nnnn,
0000 to 9999
3
TIP DRESS of STEP1
n,
0:OFF 1:ON(X)
4
COUNT of STEP2
nnnn,
0000 to 9999
5
RATIO of STEP2
nnn,
050 to 200(%)
6
TIP DRESS of STEP2
n,
0:OFF 1:ON(X)
7
COUNT of STEP3
nnnn,
0000 to 9999
8
RATIO of STEP3
nnn,
050 to 200(%)
9
TIP DRESS of STEP3
n,
0:OFF 1:ON(X)
10
COUNT of STEP4
nnnn,
0000 to 9999
11
RATIO of STEP4
nnn,
050 to 200(%)
12
TIP DRESS of STEP4
n,
0:OFF 1:ON(X)
13
COUNT of STEP5
nnnn,
0000 to 9999
14
RATIO of STEP5
nnn,
050 to 200(%)
15
TIP DRESS of STEP5
n,
0:OFF 1:ON(X)
16
COUNT of STEP6
nnnn,
0000 to 9999
17
RATIO of STEP6
nnn,
050 to 200(%)
18
TIP DRESS of STEP6
n,
0:OFF 1:ON(X)
19
COUNT of STEP7
nnnn,
0000 to 9999
20
RATIO of STEP7
nnn,
050 to 200(%)
21
TIP DRESS of STEP7
n,
0:OFF 1:ON(X)
22
COUNT of STEP8
nnnn,
0000 to 9999
23
RATIO of STEP8
nnn,
050 to 200(%)
24
TIP DRESS of STEP8
n,
0:OFF 1:ON(X)
25
COUNT of STEP9
nnnn,
0000 to 9999
26
RATIO of STEP9
nnn,
050 to 200(%)
27
TIP DRESS of STEP9
n,
0:OFF 1:ON(X)
28
STEP2 REPEAT
nn,
01 to 99
29
CAP CHANGE
nnnn
0000 to 9999
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...