APPENDIX C: SYSTEM TIMING
IS-300CA INVERTER POWER SUPPLY
990-418
C-11
The timing charts below are for IS-300CA Advanced ONLY
CHAINING Function
This function can call up welding multiple SCHEDULEs in order to perform them while the
1ST STAGE signal and the 2ND STAGE signal are input.
The SCHEDULE used in the chaining function is set in CHAINING on the FORCE SETUP &
MONITOR screen. For details, see
Chapter 3, Section III, Force Setup & Monitor Screen
.
Even if start is maintained, the sequence executes the final SCHEDULE and ends.
[Example] At 1-stage start operation
(For 2-stage start, the start method is different, but the operation after start is the same.)
In this example, the CHAINING settings for SCHEDULE1, 2, 5, and 6 are ON, and those for
other SCHEDULEs are OFF.
Since the 2ND STAGE signal is OFF when the sequence of SCHEDULE5 ends,
SCHEDULE6 is not executed.
Next, when the 2ND STAGE signal is input, the sequence starts from the first SCHEDULE1.
T1
SCH1
SCH2
SCH5
OFF1
OFF2
T2
SCH6
VALVE OUTPUT
END (out )
ERROR (out )
(When fau lt occur . )
STEP END (out )
(When steps comp leted . )
ERROR RESET ( in )
STEP RESET ( in )
(Note 1 )
We ld ing sequence
T1 : T ime set by [DELAY START SET ]
OFF1 : OFF t ime set by [SCHEDULE1 ]
OFF2 : OFF t ime set by [SCHEDULE2 ]
1ST/2ND STAGE ( in )
T2 : Durat ion o f END output s igna l
(Note 1)
When the VALVE MODE setting is 1 VALVE, the valve selected from EXSOL1
to 4 is output.
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...