CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-3
b. CONTROL #
Input the identification No. of your Power Supply. If you have two or more Power Supply units,
input 01 for the first one, 02 for the second one, 03 for the third one, and so on. Used for
communication.
c. PROGRAMED DATE
Input the date on which a schedule is set as data. The date does not affect the set schedule. When
the Power Supply memory is initialized, the date is also initialized to the date on which the ROM
version is created.
d. POWER SOURCE FREQUENCY
The frequency of the welding power is measured and indicated automatically.
e. LANGUAGE
Select the language from Japanese and English.
f. MA-660A the Pendant ROM VERSION #
Indicates the ROM version No. of the Pendant.
g. MA-660A the Pendant (IS-300CA) PROGRAM VERSION
Indicates the program version No. of the Power Supply’s screen display part.
h. IS-300CA ROM VERSION #
Indicates the ROM version No. of the Power Supply.
3. SCHEDULE Screen
Up to 255 welding schedules can be set on the Power Supply. These schedules are indicated as
SCHEDULE #1 to #255.In the SCHEDULE screen, there is a Current and time setting screen and a
PULSATION and transformer screen.
CURRENT and TIME Setting Screen
This screen is used to set the SCHEDULE No., length of weld time, welding current, and so on.
The ms mode or CYC mode can be changed via WELD TIME (
refer to Section 9 below
) on the
MODE SELECT screen.
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...