CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-57
After the completion of welding sequence, the CALIBRATION CONSTANT FORCE
setting is output to the electro pneumatic proportional valve (ANALOG OUT).
Set AIR CYLINDER DIAMETER and MAX AIR PRESSURE to set the maximum force.
(CALIBRATION LOW and HIGH settings are not used.)
Check the force before using this.
2: Mode using the electro pneumatic proportional valve. The electro pneumatic proportional
valve (ANALOG OUT) is output.
At the operation of welding sequence, SQD, SQZ, WE1, CO1/WE2, CO2/WE3, and
HOLD settings are output to the electro pneumatic proportional valve (ANALOG OUT).
After the completion of welding sequence, the HOLD setting is output to the electro
pneumatic proportional valve (ANALOG OUT).
Set AIR CYLINDER DIAMETER and MAX AIR PRESSURE to set the maximum force.
(CALIBRATION LOW and HIGH settings are not used.)
Check the force before using this.
3: Mode using the electro pneumatic proportional valve. The electro pneumatic proportional
valve (ANALOG OUT) is output.
Regardless of welding sequence operation, the CALIBRATION CONSTANT FORCE
setting is output to the electro pneumatic proportional valve (ANALOG OUT).
Set AIR CYLINDER DIAMETER and MAX AIR PRESSURE to set the maximum force.
(CALIBRATION LOW and HIGH settings are not used.)
Check the force before using this.
4: Mode using the electro pneumatic proportional valve. The electro pneumatic proportional
valve (ANALOG OUT) is output.
At the operation of welding sequence, SQD, SQZ, WE1, CO1/WE2, CO2/WE3, and
HOLD settings are output to the electro pneumatic proportional valve (ANALOG OUT).
After the completion of welding sequence, the CALIBRATION CONSTANT FORCE
setting is output to the electro pneumatic proportional valve (ANALOG OUT).
Set CALIBRATION LOW and HIGH to set the maximum force. (AIR CYLINDER
DIAMETER, MAX AIR PRESSURE and AIR PRESSURE UNIT settings are not used.)
Check the force before using this.
b. FORCE UNIT
Select the unit of force among N, kgf and lbf.
c. AIR PRESSURE UNIT
Select the unit of pneumatic pressure among Mpa, bar and psi.
d. AIR CYLINDER DIAMATER
Used when FORCE CONTROL MODE is 1 to 3.
Set the diameter of pneumatic cylinder.
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...