APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-4
990-418
Protocol
1.
Single-directional Communication Mode
(When
-->
is selected at
COMM CONTROL
in
MODE SELECT Screen
)
a) Monitor Data
IS-300CA Basic Data strings:
!01001:m,120,1.20,0.50,00.60,20.0,200,2.00,1.50,03.00,40.0,
A B C D E
F
G
H
I
J
K
L
M
300,2.50,2.00,05.00,50.0,2,0010,5,0100,2222,555555[CR][LF]
N O
P
Q
R S T U V
W
X
IS-300CA Advanced / EtherNet/IP
TM
Data strings:
!01001:m,120,01.20,0.50,00.60,20.0,200,02.00,1.50,03.00,40.0,
A B C D E F G H I J K L M
300,02.50,2.00,05.00,50.0,2,0010,5,0100,1,0000,1,0000,01,100,
N O P Q R S T U V W X Y Z AA AB
0100,2222,555555,05000,05000,05000,05000,05000,05000,+00.100,
AC AD AE
AF AG AH
AI AJ AK
AL
+01.120[CR][LF]
AM
A
Device No.
Fixed to 2 digits (01 to 31)
B
Schedule No.
Fixed to 3 digits (001 to 255)
C
Unit of monitor time
m: ms
C: CYC
D
Monitor time of WE1
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
E
Monitor current of WE1
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
F
Monitor voltage of WE1
Fixed to 4 digits (0.00 to 9.99) (V)
G
Monitor power of WE1
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 999.9) (kW)
H
Monitor pulse width of WE1
Fixed to 4 digits (10.0 to 99.9) (%)
I
Monitor time of WE2
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
J
Monitor current of WE2
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
K
Monitor voltage of WE2
Fixed to 4 digits (0.00 to 9.99) (V)
L
Monitor power of WE2
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 999.9) (kW)
M
Monitor pulse width of WE2
Fixed to 4 digits (10.0 to 99.9) (%)
N
Monitor time of WE3
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...