APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-18
990-418
Item
Contents
Character
String
Range
18
COMM MODE
n,
0: RS-485 1: RS-232C
19
MONI DISP MODE
n,
0: NORMAL 1: LAST
20
PRESET COUNT
n,
0: TOTAL/GOOD 1: WELD/WORK
21
TOTAL/GOOD of PRESET COUNT nnnnnn,
000000 to 999999
22
WELD of WELD/WORK,
PRESET COUNT
nnnn,
0000 to 9999
23
WORK of WELD/WORK, PRESET
COUNT
nnnnnn,
000000 to 999999
24
NO CURRENT TIME
nn,
01 to 99 (ms)
25
NO CURRENT LEVEL
n.nn,
0.00 to 9.99 (kA)
26
NO VOLTAGE LEVEL
n.nn,
0.00 to 9.99 (V)
27
MONITOR FIRST TIME
nn,
00 to 15 (ms)
28
MONITOR SLOPE MODE
n,
0: EXCLUDE 1: INCLUDE
29
WELD STOP OFF TIME of WELD1 nnn,
000 to 999 (ms)
30
WELD STOP OFF TIME of WELD2 nnn,
000 to 999 (ms)
31
WELD STOP OFF TIME of WELD3 nnn,
000 to 999 (ms)
32
OUTPUT MODE of NG SIGNAL
SELECT
n,
0: N.C. 1: N.O.
33
TIME-OVER of NG SIGNAL
SELECT
n,
0: ERROR 1: CAUTION
34
CURR-OVER of NG SIGNAL
SELECT
n,
0: ERROR 1: CAUTION
35
VOLT-OVER of NG SIGNAL
SELECT
n,
0: ERROR 1: CAUTION
36
POWER-OVER of NG SIGNAL
SELECT
n,
0: ERROR 1: CAUTION
37
PULSE-OVER of NG SIGNAL
SELECT
n,
0: ERROR 1: CAUTION
38
NO CURR of NG SIGNAL SELECT n,
0: ERROR 1: CAUTION
39
WRK ERR of NG SIGNAL SELECT n,
0: ERROR 1: CAUTION
40*
1
PROGRAM PROTECT
n
0: OFF 1: ON
*1 Items inhibited from setting (When setting data, omit these items.)
“,” is not transmitted, too. In other words, the 4th item (DELAY START SET) will be the first
data.
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...