CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
3-22
990-418
8. COPY SETUP DATA Screen
The Pendant can store data as shown in the figure below. When the Pendant is connected to the
Power Supply, the data stored in the Power Supply memory is displayed on the Monitor Panel. When
the data is changed and the
ENTER
key is pressed, the contents of the memory of the Power Supply
are overwritten by the new setting.
NOTE:
The
Pendant
stores data for only one
unit
.
When two or more the Power Supply units are
used and the contents of the memory of the first unit need to be copied to the second unit, copy the
data from the first unit to the memory of the Pendant temporarily, then copy this data to the second
unit.
Move the cursor
to the required item then press the ENTER key; the data will be copied.
a.
IS-300CA
MA-660A
. The data in IS-300CA is copied to MEMORY of MA-660A. When
copy is complete,
<END>
is displayed.
b.
IS-300CA
MA-660A.
The data in MEMORY of MA-660A is copied to IS-300CA. When
copy is complete,
<END>
is displayed.
c.
SCHEDULE [A]
SCHEDULE [B]–[C].
This function is used to copy the SCHEDULE
(welding condition). The Power Supply can set up to 255 schedules, indicated as SCHEDULE
#1–#255. This function is also used to change from the SCHEDULE #1 setting, to perform
welding according to another schedule.
EXAMPLES
:
Schedule #2
can be set by switching from
SCHEDULE #1
as follows:
SCHEDULE
001
SCHEDULE
002
–
002
.
Be sure to press the
ENTER
key before
moving the cursor).
Move the cursor to the left of the letters of
SCHEDULE
and press the
ENTER
key. The
data for
SCHEDULE #1
is copied to
SCHEDULE #2
through this operation. Call up #2
on the
SCHEDULE screen
, and change the values, if necessary.
SCHEDULE #1
can be copied immediately to
SCHEDULE #2
via
SCHEDULE #4
through
the following setting:
SCHEDULE 001 -----> SCHEDULE 002 - 004
NOTE:
Do
not
operate the Pendant until the copy is complete.
(a)
(b)
(c)
Содержание IS-300CA
Страница 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Страница 26: ......
Страница 30: ......
Страница 92: ......
Страница 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...
Страница 162: ...APPENDIX E EtherNet IPTM COMMUNICATIONS IS 300CR INVERTER POWER SUPPLY E 2 990 418 System Hardware Overview...
Страница 208: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...