CHAPTER 1: SYSTEM DESCRIPTION
IS-300CA INVERTER POWER SUPPLY
990-418
1-3
Section II: System Components
External Input / Output Signals
See Appendix B for connections.
The program monitor connector on the front panel is for the pendant.
The RS-232 communications connector is also on the front panel.
The IS-300CA power supply is typically sold with Amada Weld Tech’s IT Transformers with built-in
current coil, thermal switch and voltage cable connection. The power supply is, therefore, calibrated for
the IT Transformer coils, 220ma/kA.
Do not use an external coil connected to the front if you are using an IT Transformer with the transformer
sense cable connected. If you choose to use an external coil, only a coil with a response of 220mA/kA.
The supply may need to be re-calibrated to be accurate.
Most users will make external connections on the back of the unit. For additional features, remove the
rear-mounted box assembly to access terminal connector TB1.