Receiving
Remove the relay from the container in which it is received and inspect for obvious
damage. If damage has been sustained in transit, a claim should be made
immediately to the transport company concerned and a report sent to the nearest
ALSTOM T&D Protection & Control Ltd branch office or agent.
1.2
Handling
The relay in its case is extremely robust and no special precautions are necessary.
However, to prevent the ingress of dirt, it is strongly advised that modules are not
removed from the case.
1.3
Storage
If not required for immediate use, return the relay to its original wrapper and
carton and store in a clean dry place. The silica gel unit supplied with relays
delivered outside the United Kingdom should be heated at 60
°
– 70
°
C for one
hour before being replaced.
1.4
Installation
Relays should be installed in a location free from excessive vibration.
The relay cases can be supplied for either rack or panel mounting.
1.5
Rack mounting
Relays for rack mounting are supplied in cases designed for housing in standard
19 inch (483mm) racks.
1.6
Panel mounting
Relays can be supplied for either flush or semi-projecting panel mounting.
Panels should be vertical to within 5
°
. Dimensions, fixing details and cut out sizes
for the cases are shown in the relevant case outline drawing.
Flush mounted relays are inserted from the front into the panel cut out and secured
by means of the clamps provided which are bolted to tapped bosses at the back of
the case. The clamps are adjustable to accommodate different panel thicknesses.
Semi-projecting mounted relays are fitted with an extending collar and are secured
using the same clamps as described for flush mounted relays.
When installation is complete the relays must be set up and commissioned as
described in relevant instruction.
1.7
Earthing
The relay case earthing terminal on the rear of the relay case (see Figure 3,
Chapter 2) must be connected to earth (ground).
Содержание SHPM 101
Страница 1: ...Service Manual Quadramho Distance Protection Type SHPM 101...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 13: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 1 Application...
Страница 14: ......
Страница 44: ......
Страница 55: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 2 Description Technical Data...
Страница 56: ......
Страница 137: ...SERVICE MANUAL R5888C QUADRAMHO Chapter 2 Appendix A Page 1 of 71 Figure 1 Quadramho Quiet area Interface area...
Страница 208: ......
Страница 209: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 3 Electronic Module Housing...
Страница 210: ......
Страница 211: ...Quadramho Distance Protection Type SHPM101 Service Manual Chapter 4 Installation...
Страница 212: ......
Страница 214: ......
Страница 216: ......
Страница 217: ...Quadramho Distance Protection Type SHPM101 Service Manual Chapter 5 Commissioning Instructions...
Страница 218: ......
Страница 262: ...SERVICE MANUAL R5888B QUADRAMHO Chapter 5 Appendix A Page 18 of 18 Figure 11c LAG LEAD VA VC VB 0 90 270 180...
Страница 266: ......
Страница 280: ......
Страница 282: ......
Страница 285: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 6 Problem Analysis...
Страница 286: ......
Страница 288: ......
Страница 310: ...SERVICE MANUAL R5888B QUADRAMHO Chapter 6 Addendum A Page 10 of 15 Figure 6 Lenticular characteristic X R 80...
Страница 316: ......
Страница 317: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 7 Relay Identification...
Страница 318: ......
Страница 320: ......
Страница 323: ...Quadramho Distance Protection Type SHPM 101 Service Manual Chapter 8 Special Variations...
Страница 324: ......
Страница 326: ......
Страница 332: ......
Страница 335: ......