Managing Redundancy in a Stack and CMM
Managing CMM Directory Content
page 4-28
OmniSwitch 6800/6850/9000 Switch Management Guide
December 2007
To synchronize the secondary CMM to the primary CMM, enter the following command at the prompt:
-> copy flash-synchro
The
copy flash-synchro
command is described in detail in the
OmniSwitch CLI Reference Guide
.
Note.
When synchronizing the primary and secondary CMMs, it is important to remember that the
boot.params
file and the switch date and time are not automatically synchronized. See the
Getting Started
Guide
for information on the
boot.params
file, and
Chapter 1, “Managing System Files,”
for information
on setting the switch date and time. The date and time are synchronized using the
system time-and-date
synchro
command.
Synchronizing the System Date and Time
To synchronize the system date and time, use the
system time-and-date synchro
command. This
command synchronizes the secondary CMM date and time to the primary CMM date and time.
Enter the command as shown:
-> system time-and-date synchro
CMM Switching Fabric
Each OS9000 CMM module contains hardware and software elements to provide management functions
for the OS9000 system. The OS9000 CMM module also contains the switch fabric for the OS9000 system.
User data flowing from one NI module to another passes through the switch fabric.
The OS9000 will operate with one or two CMM modules installed.
If there are two CMM modules, one management processor is considered “primary” and is actively
managing the system. The other management processor is considered “secondary” and remains ready to
quickly take over management in the event of hardware or software failure on the primary. In the event of
a failure, the two processors exchange roles and the secondary takes over as primary.
The switch fabric on the CMM operates independently of the management processor. If there are two
CMM modules installed, both fabric modules are normally active. Two CMM modules must be installed
in the OS9000 to provide full fabric capacity.
If there is one CMM module installed, then there is a single management feature and performance as a
dual CMM system, but there is no “secondary” CMM. Hardware or software failures in the CMM will
result in a system reboot. The System fabric capacity is on half of the fabric capacity of a dual CMM
system.
Содержание OmniSwitch 6850 Series
Страница 12: ...Contents xii OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 20: ...page xx OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 230: ...WebView Help Using WebView page 9 20 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 274: ...Verifying the SNMP Configuration Using SNMP page 10 44 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 292: ...Index Index 6 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...