Scenario 2: Running Configuration Saved to Working Directory
The network administrator recreates Switch X’s running configuration and immediately saves the running
configuration to the working directory.
In another mishap, the power to the switch is again interrupted. The switch reboots from certified direc-
tory, overwrites all of the changes in the running configuration, and rolls back to the certified directory
(which in this case is the factory settings). However, since the configuration file was saved to the working
directory, that file is still in the working directory and can be retrieved. Since the working and certified
directories are not exactly the same, the switch is running from the certified directory.
This is illustrated in the diagram below:
Running Configuration Saved to Working Directory
It is important to note that in the above scenario, the switch is using the configuration file from the certi-
fied directory, and not the working directory. The changes made and saved to the working directory are
not in effect. The switch can be booted from the working directory by using the
reload working
command.
R
W
C
R
W
C
R
W
C
R
W
C
1. Switch boots
from certified
directory using
factory configura-
tion settings.
Since the working
and certified
directories are the
same, it will be
running from the
working
direc-
tory.
2. Changes are
made to the run-
ning configura-
tion and stored in
the running con-
figuration, and
then saved to the
working directory.
3. Power is inter-
rupted and the
switch goes down.
4. Switch reboots
from the certified
directory by using
factory configura-
tion settings; saved
configuration file
is still in the work-
ing directory.
Since the working
and certified direc-
tories are
not
the
same, it will be
running from the
certified
directory.
Содержание OmniSwitch 6850 Series
Страница 12: ...Contents xii OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 20: ...page xx OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 230: ...WebView Help Using WebView page 9 20 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 274: ...Verifying the SNMP Configuration Using SNMP page 10 44 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 292: ...Index Index 6 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...