Managing CMM Directory Content
Managing the Directory Structure (Non-Redundant)
OmniSwitch 6800/6850/9000 Switch Management Guide
December 2007
page 4-19
Note.
If the switch is rebooted before using the
copy certified working
command, the switch will be
running from the certified directory as the working and certified directories are not the same. This behav-
ior is described in
“Where is the Switch Running From?” on page 4-4
.
To reboot the switch from the working directory, enter the following command at the prompt, along with a
timeout period (in minutes), as shown:
-> reload working rollback-timeout 5
At the end of the timeout period, the switch will reboot again normally, as if a
reload
command had been
issued.
Note.
It is important to certify the working directory and synchronize the stack as soon as the validity of
the software is established in OmniSwitch 6800 and 6850 switches only. Stacks booted from the working
directory or unsynchronized stacks are at risk of mismanaging data traffic due to incompatibilities in
different versions of switch software. Certifying the working directory is described in
“Copying the Work-
ing Directory to the Certified Directory” on page 4-21
, while synchronizing the switch is described in
“Synchronizing the Primary and Secondary CMMs” on page 4-27
.
Rebooting the Switch from the Working Directory with No Rollback Timeout
It is possible to reboot from the working directory without setting a rollback timeout, in the following
manner:
-> reload working no rollback-timeout
Scheduling a Working Directory Reboot
It is possible to cause a working directory reboot of the CMM at a future time by setting time parameters
in conjunction with the
reload working
command, using the
in
or
at
keywords. You will still need to
specify a rollback time-out time, or that there is no rollback.
To schedule a working directory reboot of the CMM in 3 hours and 3 minutes with no rollback time-out,
you would enter:
-> reload working no rollback-timeout in 3:03
To schedule a working directory reboot of the CMM at 8:00pm with a rollback time-out of 10 minutes,
you would enter:
-> reload working rollback-timeout 10 at 20:00
Note.
Scheduled reboot times should be entered in military format (i.e., a twenty-four hour clock).
Содержание OmniSwitch 6850 Series
Страница 12: ...Contents xii OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 20: ...page xx OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 230: ...WebView Help Using WebView page 9 20 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 274: ...Verifying the SNMP Configuration Using SNMP page 10 44 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...
Страница 292: ...Index Index 6 OmniSwitch 6800 6850 9000 Switch Management Guide December 2007...