101
Chapter 9: Various Settings
(Q-Link Functions, Setup Mode)
■
[F2] key/SYNC parameter
The following parameters are used to synchronize the DPS16 to an external MIDI device. Use the
[F2]
key to
toggle the sync operation
ON
and
OFF
. When this field is set to
ON
, the DPS16 and the external device operate
in sync as specified in the field (
2
). (Refer to Chapter 12 “MIDI Applications” for more information on the
sync operation using external devices.)
2
This field enables you to select the type of sync operation of the DPS16 and the external device. Move
the cursor to this field and turn the [JOG] wheel to select a type from the following four options.
•
MIDI CLK/MASTER
. The MIDI clock and Song Position Pointer are transmitted from the MIDI OUT jack
of the DPS16 to synchronize with the external device.
•
MTC/MASTER
.............. The MIDI timecode (MTC) is transmitted from the MIDI OUT jack. The MTC frame
rate parameter is set in Setup mode. (See page 132.)
•
MTC/SLAVE
................ The DPS16 receives the MIDI timecode (MTC) at the MIDI IN jack and synchronizes
to the timecode. The frame rate parameter is set in Setup mode. (See page 137.)
•
OFF
............................... Synchronization is turned off. (The same occurs when you press the
[F2]
key to set the
SYNC parameter to “
OFF
”.)
■
[F3] key/DIGITAL CLOCK parameter
This parameter enables you to select a digital clock source for DPS16 operation. Use the
[F3]
key to toggle
between two settings (
INT
and
DIG IN
).
•
INT
(internal clock) ................. The DPS16 follows its internal clock (default setting). For usual use, select this
setting.
•
DIG IN
(external clock) .......... The DPS16 locks to the external digital clock.
✐
TIP :
When a digital signal is input from the DIGITAL IN jack of the DPS16, select “
DIG IN
” (external
clock) to obtain quality signal.
Track View function
This function enables you to zoom the Track View window on the main screen in and out.
[F1]
[F2]
[F3]
[F4]
■
[F1] key/ZOOM OUT
Press the
[F1]
key to zoom out the Track View window horizontally. The Zoom Out function does not provide
any parameters.
■
[F2] key/ZOOM IN
Press the
[F2]
key to zoom in the Track View window horizontally. The Zoom In function does not provide any
parameters.
➸
NOTE :
With this function, the
[F3]
key does not have any parameters or functions.