8
3. INSTALLATION
3.1
CONNECTING THE EQUIPMENT TO
THE MAIN SUPPLY
The equipment works within an input range of
±10%.
Check to ensure that the power outlet is equipped
with a fuse that is capable of carrying the amps
indicated on the data plate of this unit.
3.2 SELECTING A LOCATION
Special installation may be required
where gasoline or volatile liquids are present
(See NEC Article 511 or CEC Section 20). Do
not move or operate this equipment where it
could tip over. When selecting a location for
this equipment, ensure that the following
guidelines are followed:
1.
Use data plate to determine input power
requirements.
2
. The operator must have unobstructed access to
all controls and equipment connections.
3
. Do not position equipment in small, closed
places. Ventilation of the power source is
extremely important. Make sure that the lou-
vers on the side panels are not obstructed and
that there is no risk of obstruction during opera-
tion.
4
. Avoid areas where dust or other objects could
be sucked into the system.
5
. Equipment must not obstruct corridors or work
activities of other personnel.
6
. Position the power source securely to avoid
falling or overturning.
7
. Understand the risk of falling equipment situat-
ed in overhead positions.
3.3 CHANGING POLARITY
T U R N O F F W E L D E R B E F O R E M A K I N G
CONNECTIONS.
(Consult wire data to verify polarity require-
ments.)
DCEN (Straight Polarity)
1. Connect the ground cable to the positive recep-
tacle inside the unit.
2
. Connect the power cable to the negative recep-
tacle inside the unit.
DCEP (Reverse Polarity)
1
. Connect the ground cable to the negative
receptacle inside the unit.
2
. Connect the power cable to the positive recep-
tacle inside the unit.
INSTALLING GAS HOSE AND REGULATOR
1
. Install the gas hose on the inlet connection
located on the rear of the machine.
2
. Install the regulator on the cylinder outlet con-
nection located on the top of the compressed
gas cylinder.
3
. Connect the male gas hose connection to the
female regulator connection.
3.4 INSTALLING WELDING GUN
T U R N O F F W E L D E R B E F O R E M A K I N G
CONNECTIONS.
Before connecting the torch, ensure that the drive
rolls, gun liner and contact tip match the diameter
of the wire being used.
When installing the welding gun, follow the
sequence described below.
Содержание M 132
Страница 9: ...INSTALLING WELDING GUN TURN OFF WELDER BEFORE MAKING CONNECTIONS 9 1 4 2 3 ...
Страница 22: ...1 4 2 3 22 INSTALLATION DE LA TORCHE DE SOUDAGE ÉTEINDRE LE POSTE AVANT DE PROCÉDER AUX CONNEXIONS ...
Страница 34: ...1 4 2 3 34 INSTALACIÓN APAGUE LA SOLDADORA ANTES DE REALIZAR CONEXIONES ...
Страница 39: ... ...
Страница 42: ...42 ELECTRICAL DIAGRAM SCHÉMA ÉLECTRIQUE DIAGRAMA ELÉCTRICO M 132 ...
Страница 43: ...43 ELECTRICAL DIAGRAM SCHÉMA ÉLECTRIQUE DIAGRAMA ELÉCTRICO M 172 ...
Страница 44: ...44 SPARE PARTS LIST PIECES DETACHEES LISTA PIEZAS DE RICAMBIO M 132 ...
Страница 46: ...46 SPARE PARTS LIST PIECES DETACHEES LISTA PIEZAS DE RICAMBIO M 172 ...
Страница 49: ...49 ...