236
3
English URL
www.agilent.com/find/products
E9321A
E9322A
E9323A
E9325A
E9326A
E9327A
Peak and Average Power Meters (cont.)
Power Meters
E9320 Family Peak and Average Power Sensors
The E9320 power sensors must be used with an E9288A, B or C sen-
sor cable and only operate with the EPM-P or P-Series power meters.
These sensors have two measurement paths, one for peak and
time-gated measurements (a fast sampled path) and another for
stable, low-level average power measurements.
High Performance Sensors
The E932x sensors have two frequency ranges, from 50 MHz to
6 GHz to cover most wireless communications applications, and a
higher frequency range 50 MHz to 18 GHz. Each frequency range has
a choice of 3 different video bandwidth sensors:
• 300 kHz for TDMA signals, for example GSM
• 1.5 MHz for cdmaOne
• 5 MHz for W-CDMA and cdma2000
Using just one sensor, user’s can measure W-CDMA, cdmaOne
and TDMA as each sensor provides a high, medium and low video
bandwidth setting, selectable by the meter. So user’s can select the
modulation bandwidth required for their application, while main-
taining the maximum dynamic range.
Fast Measurement Speed
The E9320 power sensors provide fast measurement speed, over the
GPIB, up to 1,000 corrected readings per second, with the E4416A
power meter.
Optimum Measurement Accuracy and Repeatability
To minimize the sensor and source mismatch, one of the main con-
tributors to the overall measurement uncertainty, the E9320 sensors
have a low SWR specification (1.15 for signals <+10 dBm, 50 MHz
to 2 GHz). Comprehensive error correction is also provided as the
calibration factors, linearity, and temperature compensation data
are all stored within the E9320 sensor’s EEPROM.
Specifications
Sensor
Max. Meas.
Frequency
Power
Max.
Model
Bandwidth
Range
Range
Power
E9321A
300 kHz
50 MHz to
–65 to +20 dBm (max.)
+23 dBm
6 GHz
average
E9322A
1.5 MHz
50 MHz to
–60 to +20 dBm (max.)
+23 dBm
6 GHz
average
E9323A
5 MHz
50 MHz to
–60 to +20 dBm (max.)
+23 dBm
6 GHz
average
E9325A
300 kHz
50 MHz to
–65 to +20 dBm (max.)
+23 dBm
18 GHz
average
E9326A
1.5 MHz
50 MHz to
–60 to +20 dBm (max.)
+23 dBm
18 GHz
average
E9327A
5 MHz
50 MHz to
–60 to +20 dBm (max.)
+23 dBm
18 GHz
average
Key Literature
Product Overview, p/n 5980-1471E
Technical Specifications, p/n 5980-1469E
Configuration Guide, p/n 5965-6381E
Application Note 1449 Fundamentals of RF and Microwave Power
Measurements, Part 1 p/n 5988-9213EN, Part 2 p/n 5988-9214EN,
Part 3 p/n 5988-9215EN, Part 4 p/n 5988-9216EN
Application Note 64-4, Four Steps for Better Power Measurements,
p/n 5965-8167EN
Product Note, Choosing the Right Power Meter and Sensor,
p/n 5968-7150E
Application Note 1438, EPM-P Series Power Meters Used in Radar and
Pulse Applications, p/n 5988-8522EN
Ordering Information
E9321A
Power Sensor, 50 MHz to 6 GHz, 300 kHz Bandwidth
E9321A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
E9322A
Power Sensor, 50 MHz to 6 GHz, 1.5 MHz Bandwidth
E9322A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
E9323A
Power Sensor, 50 MHz to 6 GHz, 5 MHz Bandwidth
E9323A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
E9325A
Power Sensor, 50 MHz to 18 GHz, 300 kHz Bandwidth
E9325A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
E9326A
Power Sensor, 50 MHz to 18 GHz, 1.5 MHz Bandwidth
E9326A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
E9327A
Power Sensor, 50 MHz to 18 GHz, 5 MHz Bandwidth
E9327A-A6J
Supplies ANSI Z540 Certificate of Calibration with Data
• Operates with the new EPM-P Series Power Meters
(E4416A and E4417A)
• Provides peak and average power measurements
• Fast measurement speed over the GPIB (up to 1,000 readings
per second)
• 300 kHz, 1.5 MHz and 5 MHz video (modulation) bandwidths
• Wide dynamic range sensors
• Calibration factors stored in EEPROM
E9320 Family Peak and Average Power Sensors
Содержание All
Страница 1: ......