![Agilent Technologies All Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/agilent-technologies/all/all_catalog_2868003028.webp)
75
86100C
DCA-J
English URL
www.agilent.com/find/products
3
86100C Infiniium DCA-J (cont.)
Optical/Transmission
Data Displays (Option 200 Jitter Analysis)
TJ histogram, RJ/PJ histogram, DDJ histogram, Composite histogram,
DDJ versus Bit position, Composite DDJ, Bathtub curve, PJ Analysis,
SRJ analysis, Aliased Spectrum, PJ Waveforms
Measurements (Option 201 Advanced Waveform Analysis)
Pattern waveform
Data Displays (Option 201 Advanced Waveform Analysis)
Equalized waveform
Measurements (Option 300 Advanced Amplitude Analysis)
Total Interference (TI), Deterministic Interference (DI), Random Noise
(RN), Data Dependent Interference (DDI), Inter-Symbol Interference (ISI),
Periodic Interference (PI)
Data Displays (Option 300 Advanced Amplitude Analysis)
TI histogram, RI/PI histogram, DDI histogram, Composite histogram, DDI
versus Bit position
Oscilloscope Mode
Time
Rise Time, Fall Time, Jitter RMS, Jitter p-p, Period, Frequency, + Pulse
Width, – Pulse Width, Duty Cycle, Delta Time, [Tmax, Tmin, Tedge –
remote commands only]
Amplitude
Overshoot, Average Power, V amptd, V p-p, V rms, V top, V base, V max,
V min, V avg, Optional Modulation
Amplitude (OMA)
86100C Family Plug-in Module Matrix
Module Option Number
Number
Wavelength
Unfiltered Electrical Fiber Mask
of of Range
Optical
Bandwidth Input Test
Optical
Electrical (nm)
Bandwidth (GHz)
(µm) Sensitivity Probe
Channels Channels
(GHz)
(dBm)
Power
1
Optical/Electrical
86105B 111
1
1
1000 – 1600 15
20
9
–12
• • • • • • •
112
1
1
1000 – 1600 15
20
9
–12
• •
• •
• • • • • • •
113
1
1
1000 – 1600 15
20
9
–12
• • • •
• • • • • • •
86105C 100
2
1
1
750 – 1650
8.5
20
62.5 –20
• • • • • • • • • • • •
200
1
1
750 – 1650
8.5
20
62.5 –16
• • • • • • •
300
2
1
1
750 – 1650
8.5
20
62.5 –16
• • • • • • • • • • • • • • • • • • •
86106B
1
1
1000 – 1600 28
40
9
–7
•
•
410
1
1
1000 – 1600 28
40
9
–7
•
• • • • •
86116A
1 1 1000
–
1600
53 63 9
—
•
86116B
1 1 1480
–
1620
65 80 9
—
86116C
1,3
1 1 1480
–
1620
65 80 9
–3
• •
Dual/Electrical
54754A
0 2 —
—
18
—
—
•
86112A
0 2 —
—
20
—
—
•
86117A
0 2 —
—
50
—
—
86118A
0 2 —
—
70
—
—
1
Module has receptacle to supply power for external probe. For modules without a probe power receptacle, use the 1143A Probe Power Supply.
2
Pick any 4 rates (155 Mb/s to 8.5 Gb/s).
3
This module is not compatible with the 86100A and 86100B Digital Communication Analyzer (DCA) mainframes. If you would like to upgrade older DCAs contact Agilent Technologies
and ask for current trade-in deals.
Filtered Data Rates
Mb/s
Gb/s
Eye/Mask Mode
NRZ Eye Measurements
Extinction Ratio, Jitter RMS, Jitter p-p, Average Power, Crossing
Percentage, Rise Time, Fall Time, One Level, Zero Level, Eye Height, Eye
Width, Signal to Noise (Q-Factor), Duty Cycle Distortion, Bit Rate, Eye
Amplitude
RZ Eye Measurements
Extinction Ratio, Jitter RMS, Jitter p-p, Average Power, Rise Time, Fall
Time, One Level, Zero Level, Eye Height, Eye Amplitude, Opening Factor,
Eye Width, Pulse Width, Signal to Noise (Q-Factor), Duty Cycle, Bit Rate,
Contrast Ratio
Mask Test
Open Mask, Start Mask Test, Exit Mask Test, Filter, Mask Test Margins,
Mask Test Scaling, Create NRZ Mask
TDR/TDT Mode (requires TDR module)
Quick TDR, TDR/TDT Setup, Normalize, Response, Rise Time, Fall Time,
Δ
Time
Modules for the Agilent 86100C Infiniium DCA-J
The Infiniium DCA has a large family of plug-in modules designed
for a broad range of data rates for optical and electrical waveforms.
The DCA-J can hold up to 2 modules for a total of 4 measurement
channels.
155
622
1063
1244/1250
2125
2488/2500
2.666
3.125
4.25
5.00
6.25
8.500
9.953
10.3125
10.51875
10.664
10.709
11.096
11.317
39.813
43.018
Содержание All
Страница 1: ......