34405A
5
1
⁄
2
Digit Dual Display Digital Multimeter
Digital Multimeters
• 120,000 count resolution
• 16 measurement functions including temperature and capacitance
• 6 built-in math functions: Null, dBm, dB, MinMax, Limit and Hold
• Up to 70 readings/s
• 0.025% DC voltage accuracy
• USB 2.0 interface (TMC-488.2-compliant)
• SCPI-compatible
• Data logging capability with DMM IntuiLink connectivity software
Affordable and Feature-rich
The 34405A provides a broad range of features and measurement
functions despite its value price, including DC voltage, DC current,
true-RMS AC voltage and AC current, 2-wire resistance, frequency,
diode test, continuity, temperature (–80°C to 150°C) and capaci-
tance (1000 pF to 10,000 µF). Six built-in math operations are avail-
able for efficient, accurate results: Null, dBm, dB, MinMax, Limit
and Hold.
Make Measurements Fast
Set up your instrument fast with 34405A’s plug-and-play USB inter-
face, and auto-detection by the bundled, award-winning Agilent IO
Libraries Suite. The 34405A comes with a dual display feature that
allows simultaneous display of two measurements on the front
panel. Its fast reading speed of 70 readings/s allows you to detect
intermittent failures and anomalies easily. With 34405A’s
store/recall function, you can configure and store complete instru-
ment setups and load them at anytime from any of the four built-in
storing states.
Remote Control and Data Logging via PC
You can use the bundled DMM Intuilink Connectivity software for
instrument control, configuration and data logging to PC via USB.
The 34405A can also be controlled remotely with industry-standard
SCPI commands. For its easy integration into different program-
ming environments, the 34405A is shipped with the Agilent IO
Library Suite, LabVIEW driver and IVI-COM driver.
Specifications
DC Specifications
1
Accuracy ± (% of r % of range)
Function Range
2
Test Current or
Input Impedance
3
1 Year
Temperature Coefficient
Burden Voltage
23°C ± 5°C
0°C – 18°C
28°C – 55°C
Voltage
100.000 mV
—
10.0 M
Ω
± 2%
0.025 + 0.008
0.0015 + 0.0005
1.00000 V
—
10.0 M
Ω
± 2%
0.025 + 0.006
0.0010 + 0.0005
10.0000 V
—
10.1 M
Ω
± 2%
0.025 + 0.005
0.0020 + 0.0005
100.000 V
—
10.1 M
Ω
± 2%
0.025 + 0.005
0.0020 + 0.0005
1000.00 V
—
10.0 M
Ω
± 2%
0.025 + 0.005
0.0015 + 0.0005
Resistance
100.000
Ω
1.0 mA
—
0.05 + 0.008
4
0.0060 + 0.0008
1.00000 k
Ω
0.83 mA
—
0.05 + 0.005
4
0.0060 + 0.0005
10.0000 k
Ω
100 µA
—
0.05 + 0.006
4
0.0060 + 0.0005
100.000 k
Ω
10.0 µA
—
0.05 + 0.007
0.0060 + 0.0005
1.00000 M
Ω
900 nA
—
0.06 + 0.007
0.0060 + 0.0005
10.0000 M
Ω
205 nA
—
0.25 + 0.005
0.0250 + 0.0005
100.000 M
Ω
205 nA||10 M
Ω
—
2.00 + 0.005
0.3000 + 0.0005
Current
10.0000 mA
<0.2 V
—
0.05 + 0.015
0.0055 + 0.0005
100.000 mA
<0.2 V
—
0.05 + 0.005
0.0055 + 0.0005
1.00000 A
<0.5 V
—
0.20 + 0.007
0.0100 + 0.0005
10.0000 A
<0.6 V
—
0.25 + 0.007
0.0150 + 0.0005
Continuity
1000
Ω
0.83 mA
—
0.05 + 0.005
0.0050 + 0.0005
Diode Test
5
1.0000 V
0.83 mA
—
0.05 + 0.005
0.0050 + 0.0005
1
Specifications are for 30 minutes warm-up, 5
1
⁄
2
digit resolution and calibration temperature 18°C – 28°C.
2
20% over range on all ranges except 1000 Vdc.
3
Input Impedance is in paralleled with capacitance <120 pF.
4
Specifications are 2-wire ohms using Math Null. If without Math Null, add 0.2
Ω
additional error.
5
Specifications are for the voltage measured at the input terminals only.