Planning
MOVING AND STORING THE INVERTER
Store the inverter in a clean and dry room in the original packaging. Always transport
the inverter in its original packaging. If the storage period exceeds two years, contact
AE Solar Energy Technical Support prior to connecting the inverter.
• The moving and storage temperature must be between -25°C (-13°F) and +70°C
(+158°F).
• Temperature fluctuations may not exceed 20°C (35°F) per hour.
• The inverter contains electrolytic capacitors that can be stored for a maximum
of two years without voltage at a temperature of 40°C (104°F).
SELECTING A LOCATION
A qualified installer should select the location for the installation of an AE 3TL
inverter. Licensed and trained installers must comply with all local and national code
requirements for the installation of electrical power systems.
When choosing a location for the unit, consider the following criteria:
• The unit is suitable for both indoor and outdoor installation; the inverter cabinet
has a NEMA 4 rating and connection box enclosure has a NEMA 3R rating.
• The optimum location of the unit is shielded from direct exposure to sunlight.
• The unit should be mounted vertically to a flat, solid surface such as concrete,
metal, or wooden structure.
• The inverter is designed and tested to produce maximum continuous output
power within the operating temperature ranges. Refer to
on page 10-5 for model-specific continuous output power
ranges.
• Ensure that adequate space has been allowed for proper cooling. Refer to
• Ensure that the drilling location is not close to any electrical wiring or plumbing
within a wall.
• The inverter is capable of emitting audible noise and should be located away
from noise-sensitive areas that are populated by people or animals.
Advanced Energy® AE 3TL Inverters
Chapter
3
570-1003552-05A
Planning
3‑1
Содержание AE 3TL 1000 Series
Страница 2: ......
Страница 12: ...Advanced Energy xii 570 1003552 05A List of Tables...
Страница 14: ...Advanced Energy xiv 570 1003552 05A List of Figures...
Страница 26: ...Advanced Energy 1 12 Safety and Product Compliance Guidelines 570 1003552 05A...
Страница 64: ...Advanced Energy 4 28 Installing 570 1003552 05A...
Страница 86: ...Advanced Energy 6 4 Operating the Arc Fault Detection Unit 570 1003552 05A...
Страница 92: ...Advanced Energy 7 6 Data Monitoring and Controls 570 1003552 05A...
Страница 110: ...Advanced Energy 9 14 Troubleshooting and Solar Energy Technical Support 570 1003552 05A...
Страница 116: ...Advanced Energy A 6 Specifications 570 1003552 05A...
Страница 118: ...Figure 11 2 AE 3TL mechanical diagram Advanced Energy B 2 System and Mechanical Diagrams 570 1003552 05A...
Страница 120: ...Advanced Energy B 4 System and Mechanical Diagrams 570 1003552 05A...