Chapter 3
6.
Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position.
7.
Holding the DIMM by the edges, remove it from its anti-static package.
8.
Position the DIMM above the socket. Align the two small notches in the bottom edge of the DIMM with the
keys in the socket (see inset in the figure above).
9.
Insert the bottom edge of the DIMM into the socket.
10.
When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into
place. Make sure the clips are firmly in place.
11.
Replace the server’s cover and reconnect the AC power cord. See the documentation that accompanied
your server chassis for instructions on installing the server’s cover.
Removing DIMMs
To remove a DIMM, follow these steps:
1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Turn off all peripheral devices connected to the server. Turn off the server.
3.
Remove the AC power cord from the server.
4.
Remove the server’s cover. See the documentation that accompanied your server chassis for instructions
on removing the server’s cover.
5.
Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket.
6.
Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package.
7.
Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets.
8.
Replace the server’s cover and reconnect the AC power cord. See the documentation that accompanied
your server chassis for instructions on installing the server’s cover.
DIMM 2A
DIMM 3B
DIMM 3A
DIMM 2B
DIMM 1A
DIMM 1B