19. Power down operation
267
19.2
IDLE mode
P
ower control register is set to ‘01h’ to enter
into IDLE mode. In IDLE mode, internal oscillation circuits
remain active. Oscillation continues and peripherals are operated normally, but CPU stops.
It is released by reset or an interrupt. To be released by an interrupt, the interrupt should be enabled
before IDLE mode. If using a reset, because the device is initialized, registers become to have reset
values.
Figure 117. IDLE Mode Release Timing by an External Interrupt
External
Interrupt
OSC
Normal Operation
Release
CPU Clock
Stand-by Mode