FL-B101D40PF Power factor (D0109) Manual
Page 1
This unit accepts an analog DC signal from a Power
Factor transducer, ranging from 4-20mA, 0-1mA,
2VDC, 5VDC, and 10VDC.
It provides a bargraph and digital display of the read-
ing in the format customary for Power Factor meters,
with the bargraph centered at PF=1.0.
Lead and lag are indicated by the bargraph extending
upward (lead) or downward (lag) with cos(theta) scale
markings from LAG 0.5 to 1.0 to LEAD 0.5.
The digital display provides a corresponding numeric
readout of the same data with LAG represented by
negative sign.
•
Choice of DC volts or DC current (header selectable )
• Mono color (red or green), 101 segment high brightness bargraph.
Vertical or optional horizontal format.
• Red 4-digit LED display with a range of -0.50, 1, +0.50
Optional green digital display.
• Auto-sensing AC/DC power supply. For voltages between
85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC
(PS2).
• 24 V DC excitation is available to power external 4/20mA
transmitters.
• Provision to connect an external programming lockout switch.
• Provision for external DIM switch to reduce the brightest
display setting by 50%.
• Optional NEMA-4 IP65, Clear dust & Splash proof front cover.
• Automatic intelligent averaging, smooths noisy signals while
providing a fast display response to real level changes.
• UL Listed
General Features
Specifications
Index
Power Factor Bargraph Indicator
• Bargraph center zero function.
• Digital display blanking.
• Four-level brightness control accessed by the button
and adjusted by the button.
Software Features
Bargraph Center Point Display Mode Selection . . . 5
Case Dimensions . . . . . . . . . . . . . . . . . . . . . . . 9
Component Layout. . . . . . . . . . . . . . . . . . . . . . 7
Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . 6
Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Controls and Indicators . . . . . . . . . . . . . . . . . . 2
Decimal Point and Brightness Selection . . . . . 5
Software Features . . . . . . . . . . . . . . . . . . . . . .
1
Software Logic Tree . . . . . . . . . . . . . . . . . . . . . 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . .
1
Two Point Analog Range Setting & Calibration . . . . 7
Two Point Digital Calibration Mode . . . . . . . . . 4
Digital Span Selection for Display . . . . . . . . . . 5
General Features . . . . . . . . . . . . . . . . . . . . . . .
1
Installation guidelines. . . . . . . . . . . . . . . . . . . . 9
Ordering Information . . . . . . . . . . . . . . . . . . . 10
Panel Adaptor. . . . . . . . . . . . . . . . . . . . . . . . . .
8
Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 6
Programming Conventions. . . . . . . . . . . . . . . . 2
LEOPARD FAMILY
Input Specs: ��������������
• Header selectable current or voltage input
signal
• Current input: 4-20mA with shunt 100ohm;
2mA range with shunt resistance 1kohm;
(Voltage at full scale current input: 2V�)
• Voltage input: 2V, 5V, 10V, input imped-
ance 1 Mohm
A/D Converter: ����������14 bit single slope
Accuracy: ������������������±(0�05% of r 2 counts)
Temp. Coeff�: �������������100 ppm/°C (Typical)
Warm up time: �����������2 minutes
Conversion Rate: ������10 conversions per second (Typical)
Digital Display: ����������4 digit 0.31" LED red (std), green (optn)
Bargraph Display: �����101 seg. bar red / 4 digit 4" LED red (std)
green(optn), horizontal (optn)
Power Supply: �����������AC/DC Auto sensing wide range supply
PS1 (std) ����������������85-265 VAC / 95-300 VDC, 50-400Hz 4.2W
PS2 �������������������������18-48 VAC / 10-72 VDC, 50-400Hz 4�2W
Operating Temp�: ������0 to 50°C
Storage Temp: �����������–20°C to 70°C
Relative Humidity: ����95% (non condensing)
Case Dimensions: ����9/64 DIN (Bezel 36Wx144Hmm)
Depth behind bezel (5�83") 148mm
Plus (0�7”) 18mm for connectors
Weight: �����������������������9�5 oz�, 12 oz when packed