FL-B101D40PF Power factor (D0109) Manual

The adapter snaps on the 36x144 mm 

(1�42”x5�69”) case and enables single unit 

or stack mounting in an existing 6” edgewise 

pointer meter cut-out�

Two bezel trim strips are provid-

ed with each adapter to finish off 

the  edge  of  each  individually 

mounted  meter  or  the  edge  of 

each stack mounted array�

Texmateʼs panel adapter enables modern DIN meters to fit in existing cutouts 
individually or stacked when replacing old 6” edgewise mechanical pointer meters�

Fits existing cut-outs for 

6” 

(150 mm) edgewise switchboard 

pointer meters from:

• Crompton

• G�E�

• Westinghouse

• Yokogawa

• and most others
Width:  43�7 mm to 48 mm

           (1�72”) to (1�89”) 

Height: 143�4 mm to 149 mm 

            (5�62”) to (5�88”)

Fits 6” Edgewise Pointer Meter Cut-Outs

Panel Adapter

When extra panel 

mounting tightness 

is required, order the 

optional screw mount clip.  

P/N.(O

PMTL

CLIP

)

Adapter uses wode jaw 

mouting slide clips�

P/N (75-DMC14436B)

Содержание Leopard Series

Страница 1: ...or Bargraph Indicator Bargraph center zero function Digital display blanking Four level brightness control accessed by the button and adjusted by the button Software Features Bargraph Center Point Display Mode Selection 5 Case Dimensions 9 Component Layout 7 Connector Pinouts 6 Connectors 6 Controls and Indicators 2 Decimal Point and Brightness Selection 5 Software Features 1 Software Logic Tree 3...

Страница 2: ...at an alternative logic branch will be followed when a particular option is present When two buttons are shown side by side and enclosed by a dotted line they must be pressed at the same time then released to go onto the next programming step If an X appears through a digit it means that any number displayed in that digit is not rel evant to the function being explained P Span 10000 P P When the a...

Страница 3: ...ut Lo cLo will occur This branch will only appear if the analog output option is installed DIGITAL SPAN SELECTION FOR ANALOG RANGE OUTPUT See Page 6 DIGITAL DISPLAY ON OFF See Page 5 BARGRAPH CENTER POINT DISPLAY MODE SELECTION See Page 6 TWO POINT ANALOG OUTPUT RANGE SETTING AND CALIBRATION See Page 7 Set the Decimal Point dp Select XX XX Bargraph Display Scale Lo Range Setting bLo Adjust to 50 B...

Страница 4: ...Digital Span Selection for Bargraph Display and the display flashes bhi and the previous setting ERROR Indicates Unsuccessful Calibration If the calibration was unsuccessful the display indicates Err the new calibration settings just entered will not take effect and the previously stored setting will remain The three most likely causes of an error during calibration are 1 The full scale and zero s...

Страница 5: ...ous brightness setting STEP D Set the Bargraph and Digital Display Brightness 1 Using the and buttons adjust the display to the desired brightness setting 4 is the brightest setting 2 Press the P button Display toggles between Cto and oFF Digital Span Selection For Bargraph Display Decimal Point and Brightness Selection Bargraph Center Point Display Mode Selection STEP G Bargraph Center Point Mode...

Страница 6: ...a unique plug and socket outline to prevent cross connection The main board uses standard right angled connectors Replacement 2 3 and 4 pin plug connectors are available see Accessories on page 10 Input Signal Pins 1 to 6 Pins 1 to 6 are reserved for the input signal conditioner See the data sheet for the selected input signal conditioner Pins 17 to 21 Rear Panel Switches Pin 19 Programming LOCK B...

Страница 7: ...ODULE 24V Exc IP07 Universal Process Input 2V 5V 10V 20V 200V 2mA 20mA Custom Custom 20mA 2mA 200V 20V 10V 5V 2V VOLTAGE CURRENT UNIVERSALPROCESS Processinput Requires Digital Calibration HI LO OFF ON 24VEXC 224C Input Range Header IP07 24V Exc on off Header Signal Type Header Voltage Current ...

Страница 8: ...l adapter enables modern DIN meters to fit in existing cutouts individually or stacked when replacing old 6 edgewise mechanical pointer meters Fits existing cut outs for 6 150 mm edgewise switchboard pointer meters from Crompton G E Westinghouse Yokogawa and most others Width 43 7 mm to 48 mm 1 72 to 1 89 Height 143 4 mm to 149 mm 5 62 to 5 88 Fits 6 Edgewise Pointer Meter Cut Outs Panel Adapter W...

Страница 9: ... IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2 SP3 SP4 Zero Span Zero Span Panel adaptor plates are available to retrofit most existing panel cutouts 31mm 1 22 These dimensions are increased by 2mm 0 08 when the metal surround case is installed For extra str...

Страница 10: ...odel number FL B101D40PF 144x36mm 101 Segment Bargraph 4 Digit Scale Factor Standard Options for this Model Number Order Code Suffix Description Display VRR Red LED Bargraph w 4 Digit Red DPM Vertical VGG Green LED Bargraph w 4 Digit Green DPM Vertical VGR Green LED Bargraph w 4 Digit Red DPM Vertical VRG Red LED Bargraph w 4 Digit Green DPM Vertical HRR Red LED Bargraph w 4 Digit Red DPM Horizont...

Отзывы: