System Manual SCK Gas Sampling System
23
Monitoring device
Purpose
Function
Reed contact
shutter
open
(only for automat-
ic shutter actuation)
Protects the gas sam-
pling probe against
damage
Prevents insertion of
the gas sampling
probe if the shutter is
not fully open
Sample gas line tem-
perature measurement
Protects the sample
gas line against con-
densation build-up in-
side
Prevents insertion of
the gas sampling
probe if the sample
gas line is not fully
heated up
Cable drag chain tem-
perature measurement
Protects the cable drag
chain against conden-
sation build-up inside
Prevents insertion of
the gas sampling
probe if the sample
gas line is not fully
heated up
The following monitoring devices belong to the probe H only:
Monitoring device
Purpose
Function
Reed contact
plunger
extended
Protects
the
plunger
against overheating
Triggers the retraction
program if end posi-
tion is not reached
Reed contact
plunger
retracted
Protects
the
plunger
against overheating
Triggers the retraction
program if end posi-
tion is not reached
Only for probe H
Содержание SCK
Страница 2: ......
Страница 16: ......
Страница 36: ......
Страница 54: ......
Страница 110: ......
Страница 222: ......
Страница 232: ......
Страница 234: ...234 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Pneumatic hydraulic interface plan ...
Страница 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Страница 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Страница 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Страница 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Страница 242: ......
Страница 243: ......