42/23-81 EN Rev. 4
System Manual SCK Gas Sampling System
229
Storing the system
Store in a place protected from the weather. Observe the designated storage tem-
peratures and humidities. The transport packing, if present, should not be removed
during storage. In the event that the gas sampling system is temporarily shut down,
ensure suitable wrapping.
Observe the following instructions with regard to storing the various modules:
Module Storage
conditions
Retractor including
probe
During storage, support the tip of the assembled gas
sampling probe.
Only store after draining all water.
Cooling module
Only store after draining all water.
Control cabinet
Store on rear side lying on pallet
Transformer
(optional)
Store on pallet
Ensure storage in a dry area (no condensation!).
Compressed-air tank
(optional)
Ensure adequate protection of the attachments.
Only store after draining all water.
Observe the following physical limits with regard to storing the various modules:
Module
Environmental conditions for storage
Retractor including
probe
Ambient temperature:
+5 °C to +55 °C; after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +55 °C
Air humidity:
Year-round average max. 75 %, short-term
max. 95 %, occasional slight condensation is permitted
Cooling module
Ambient temperature:
+5 °C to +55 °C; after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +55 °C
Air humidity:
Year-round average max. 75 %, short-term
max. 95 %, occasional slight condensation is permitted
Control cabinet
Ambient temperature:
-20 °C to +55 °C
Air humidity:
Year-round average max. 75 %, short-term
max. 95 %, occasional slight condensation is permitted
Transformer
(optional)
Ambient temperature:
-25 °C to +55 °C
Air humidity:
Year-round average max. 80 %, short-term
max. 95 %, without condensation
Compressed-air tank
(optional)
Ambient temperature:
+5 °C to +55 °C; after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +55 °C
Air humidity:
Year-round average max. 75 %, short-term
max. 95 %, occasional slight condensation is permitted
General storage
information
Storing the various
modules
Environmental
conditions
Содержание SCK
Страница 2: ......
Страница 16: ......
Страница 36: ......
Страница 54: ......
Страница 110: ......
Страница 222: ......
Страница 232: ......
Страница 234: ...234 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Pneumatic hydraulic interface plan ...
Страница 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Страница 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Страница 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Страница 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Страница 242: ......
Страница 243: ......