198
System Manual SCK Gas Sampling System
42/23-81 EN Rev. 4
Probe retractor: Checking and, if necessary, adjusting the position of
the probe
Due to changes entailed by the process or the system it may be necessary to
change the position of the gas sampling probe. Note that the tip of the probe
should be max. 30 cm in the rotary kiln after start-up. The gas sampling probe must
not be inserted further than absolutely necessary into the rotary kiln in order to
minimize impacts on the unprotected area of the probe caused by the process.
every six months or as required (kiln conversion work, process changes)
Always take the following safety measures when performing this work:
Wear the general protective equipment.
Before commencing adjustment work, turn the service switch to
ON
and secure
the service switch against unauthorized switching (with a padlock).
Additionally press the EMERGENCY STOP switch.
Do not enter the danger area around the retractor until it is at standstill and the
warning lamps and buzzer are off and the flap valve is closed.
Do not perform the adjustment work until the gas sampling system has cooled
down.
Explanation of safety measures:
Safety regulations for maintenance work on page
156.
How to check probe position:
Step Procedure
1
With the probe inserted, check the distance between the flange and
the pipe sealing device.
Target requirement:
The flange must be touching.
2
If this target requirement is not met, adjust the probe by means of
the following actions:
Adjust the tube sealing device
change vertical position
change horizontal position.
Proceed as follows to realign the tube sealing device:
Step Procedure
1
Turn service switch to
ON
position.
WARNING!
Gas sampling probe moves out of the kiln.
Do not
stand in the area of travel of the gas sampling probe or probe
carriage until the probe is completely retracted and the warn-
ing lamps go out.
2
Press EMERGENCY STOP switch and allow gas sampling probe to
cool down.
WARNING!
Risk of burning in the event of contact with the hot
probe.
Do not touch the probe until it has cooled down to be-
low 50 °C.
Probe position
Maintenance interval
Safety
measures
Instructions:
checking probe
position
Instructions:
adjusting the tube
sealing device
Содержание SCK
Страница 2: ......
Страница 16: ......
Страница 36: ......
Страница 54: ......
Страница 110: ......
Страница 222: ......
Страница 232: ......
Страница 234: ...234 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Pneumatic hydraulic interface plan ...
Страница 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Страница 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Страница 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Страница 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Страница 242: ......
Страница 243: ......