e. Lower right – indicators:
-
FWD (forward) / REV (reverse): direction of the motor rotation.
-
Flashing slowly: stopped.
-
Flashing rapidly: running, not at setpoint.
-
Steady: running, at setpoint.
-
SET: the displayed value can be modified (in the Parameter and
Reference modes).
2. RESET/EXIT – Exits to the next higher menu level without saving changed values.
Resets faults in the Output and Fault modes.
3. MENU/ENTER – Enters deeper into the menu level. In the Parameter mode, it
saves the displayed value as the new setting.
4. Up
•
Scrolls up through a menu or list.
•
Increases a value if a parameter is selected.
•
Increases the reference value in the
Reference
mode.
•
Holding the key down changes the value faster.
5. Down
•
Scrolls down through a menu or list.
•
Decreases a value if a parameter is selected.
•
Decreases the reference value in the
Reference
mode.
•
Holding the key down changes the value faster.
6. LOC/REM – Changes between local and remote control of the drive.
7. DIR – Changes the direction of the motor rotation.
8. STOP – Stops the drive in local control.
9. START – Starts the drive in local control.
Operating the frequency inverter
You operate the frequency inverter with the help of menus and keys. Select an
option, e.g. operation mode or parameter, by scrolling the
or
keys until
the desired option is visible in the display and confirm your choice by pressing the
Enter
key. With the
Exit
key, you return to the previous operation level
without saving the changes you have made. The basic control panel has five panel
modes:
Output
mode,
Reference
mode,
Parameter
mode,
Copy
mode and
Fault
mode.
By default, the inverter starts in
Output
mode, where you can start, stop, change
the direction, switch between local and remote control and monitor up to three
actual values (one at a time). To do other tasks, first return to the main menu and
select the appropriate mode.
Continues on next page
188
Product manual - FlexLoader SC 6000
3HAC051768-001 Revision: D
© Copyright 2014-2020 ABB. All rights reserved.
E Frequency inverter
Continued
Содержание FlexLoader SC 6000
Страница 1: ...ROBOTICS Product manual FlexLoader SC 6000 ...
Страница 8: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 172: ...This page is intentionally left blank ...
Страница 174: ...This page is intentionally left blank ...
Страница 176: ...This page is intentionally left blank ...
Страница 178: ...This page is intentionally left blank ...
Страница 182: ...This page is intentionally left blank ...
Страница 184: ...This page is intentionally left blank ...
Страница 186: ...This page is intentionally left blank ...
Страница 192: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 283: ......