10.10 Air preparation units
Replacing the air preparation pressure switch (if available)
Follow the instructions from the manufacturer on how to perform the replacement.
Adjust the set point and hysteresis after replacing the pressure switch.
xx1900001059
Component
Pos.
Incoming air pressure switch
A
Safety valve pressure switch
B
The values are pre-configured as follows:
•
Incoming pressure switch (left):
Switching pressure set point
2
bar/
29
psi.
Hysteresis
0.5
bar/
7
psi.
•
Pressure switch on safety valve (right)
Switching pressure set point
4
bar/
58
psi.
Hysteresis
0.0
bar/
0
psi.
Make sure that the earthing strap is electrically connected to the outer housing.
To change the values, do as follows:
1 Press
EDIT
on the pressure switch.
2 Press
EDIT
button until the display says
[SP]
.
3 Use the UP/DOWN button to set the the correct value.
4 Press
EDIT
button once and the display says
[Hy]
.
5 Use the UP/DOWN button to set the correct value.
6 Press
EDIT
twice.
7 Done.
Continues on next page
160
Product manual - FlexLoader SC 6000
3HAC051768-001 Revision: D
© Copyright 2014-2020 ABB. All rights reserved.
10 Repair
10.10 Air preparation units
Содержание FlexLoader SC 6000
Страница 1: ...ROBOTICS Product manual FlexLoader SC 6000 ...
Страница 8: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 172: ...This page is intentionally left blank ...
Страница 174: ...This page is intentionally left blank ...
Страница 176: ...This page is intentionally left blank ...
Страница 178: ...This page is intentionally left blank ...
Страница 182: ...This page is intentionally left blank ...
Страница 184: ...This page is intentionally left blank ...
Страница 186: ...This page is intentionally left blank ...
Страница 192: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 283: ......