26.04
SPEED FEED PCTRL
(see above)
Selects the source for the speed reference feedforward in position and synchron control modes.
Selects the source for the speed reference in homing and profile velocity modes.
Note:
This parameter is only for positioning applications.
Value pointer: Group and index
26.05
SPEED STEP
(see above)
Defines an additional speed step given to the input of the speed controller (added to the speed error
value).
-30000…30000 rpm
Speed step.
26.06
SPD ERR FTIME
(see above)
Defines the time constant of the speed error low pass filter.
If the used speed reference changes rapidly (servo application), the possible interferences in the
speed measurement can be filtered with the speed error filter. Reducing the ripple with filter may
cause speed controller tuning problems. A long filter time constant and fast acceleration time
contradict one another. A very long filter time results in unstable control.
See also parameter
.
0…1000 ms
Time constant for speed error low pass filter. 0 ms = filtering disabled.
26.07
SPEED WINDOW
(see above)
Defines the absolute value for the motor speed window supervision, i.e. the absolute value for the
difference between the actual speed and the unramped speed reference (
). When the motor speed is within the limits defined by this parameter, signal
bit 8 (AT_SETPOINT) value is 1. If the motor speed is not within the defined limits, bit 8 value
is 0.
0…30000 rpm
Absolute value for motor speed window supervision.
Содержание ACSM1 Series
Страница 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Страница 2: ......
Страница 4: ......
Страница 12: ...Table of contents 12...
Страница 49: ...Drive control and features 49...
Страница 282: ...Standard function blocks 282...
Страница 306: ...Application program template 306...
Страница 312: ...Control chain block diagrams 312...
Страница 331: ...331...
Страница 332: ...332...
Страница 333: ......