Standard function blocks
288
Operation
The output (OUT) is the lowest input value (IN).
Inputs
The input data type and the number of inputs (2…32) are selected by the user.
Input (IN1…IN32): INT, DINT, REAL, REAL24
Outputs
Output (OUT): INT, DINT, REAL, REAL24
MUX
(10055)
Illustration
Execution time
0.70 µs
Operation
The value of an input (IN) selected by the address input (K) is stored to the output
(OUT).
If the address input is 0, negative or exceeds the number of the outputs, the output is 0.
Inputs
The input data type and number of inputs (2…32) are selected by the user.
Address input (K): DINT
Input (IN1…IN32): INT, DINT, REAL, REAL24
Outputs
Output (OUT): INT, DINT, REAL, REAL24
SEL
(10056)
Illustration
Execution time
1.53 µs
Operation
The output (OUT) is the value of the input (IN) selected by the selection input (G).
If G = 0: OUT = IN A.
If G = 1: OUT = IN B.
Inputs
The input data type is selected by the user.
Selection input (G): Boolean
Input (IN A, IN B): Boolean, INT, DINT, REAL, REAL24
Outputs
Output (OUT): Boolean, INT, DINT, REAL, REAL24
MUX
(DINT)
79
TLA1 1 msec
(1)
K
IN1
IN2
OUT
OUT(79)
SEL
(BOOL)
80
TLA1 1 msec
(1)
G
IN A
IN B
OUT
OUT(80)
Содержание ACSM1 Series
Страница 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Страница 2: ......
Страница 4: ......
Страница 12: ...Table of contents 12...
Страница 49: ...Drive control and features 49...
Страница 282: ...Standard function blocks 282...
Страница 306: ...Application program template 306...
Страница 312: ...Control chain block diagrams 312...
Страница 331: ...331...
Страница 332: ...332...
Страница 333: ......