296 Fault tracing
2030
RESOLVER
AUTOTUNE ERR
Resolver autotuning
routines, which are
automatically started when
resolver input is activated
for the first time, have
failed.
Check the cable between resolver
and resolver interface module
(FEN-21) and the order of
connector signal wires at both ends
of the cable.
Check resolver parameter settings.
For resolver parameters and
information, see parameter group
.
Note:
Resolver autotuning routines
should always be performed after
resolver cable connection is
modified. Autotuning routines can
be activated by setting parameter
EXC SIGNAL AMPL or
EXC SIGNAL FREQ, and then
setting parameter
ENC PAR
REFRESH to
2031
ENCODER 1
CABLE
Encoder cable fault
detected.
Check the cable between FEN-xx
interface and encoder. After any
modifications in cabling, re-
configure the interface by switching
the drive power off and on, or by
activating parameter
ENC
PAR REFRESH.
2035
PS COMM
Communication errors
detected between the JCU
Control Unit and the power
unit of the drive.
Check the connections between
the JCU Control Unit and the power
unit.
2036
RESTORE
Restoration of backed-up
parameters failed.
Contact your local ABB
representative.
2037
CUR MEAS
CALIBRATION
Current measurement
calibration will occur at the
next start.
Informative alarm.
2038
AUTOPHASING
Autophasing will occur at
the next start.
Informative alarm.
Code Alarm
Cause
What to do
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...