286 Parameters
99.10
IDRUN MODE
Selects the type of the motor identification performed
at the next start of the drive in the DTC mode. During
the identification, the drive identifies the
characteristics of the motor for optimum motor
control. After the ID run, the drive is stopped.
Note:
• This parameter cannot be changed while the drive
is running.
• Once the ID run is activated, you can cancel it only
by stopping the drive.
• If the ID run has already been performed once, the
parameter is automatically set to
No.
• If ID run is not yet performed, the parameter is
automatically set to
IDstandstill
. In this case, ID
run must be performed.
• ID run can only be performed in local control (that
is when the drive is controlled through PC tool or
control panel).
• ID run must be performed every time any of the
motor parameters (
) are
changed. The parameter is automatically set to
IDstandstill
after the motor parameters are set.
• The motor must be de-coupled from the elevator
system during rotating ID run as well as if rotating
autophasing is required (that is the motor shaft
must NOT be locked and the load torque must be
< 10% during the ID run).
• The drive does not control the mechanical brake of
the motor open during the ID run. Make sure by
some other means that the brake opens if the
rotating ID run or rotating autophasing is required.
• Make sure that possible safe torque off and
emergency stop circuits are closed during the ID
run.
No /
No
No motor ID run is requested.
0
IDstandstill
Standstill ID run. The motor is injected with DC
current. With asynchronous motor, the motor shaft is
not rotating (with a permanent magnet motor the
shaft can rotate < 0.5 revolution).
Note:
Select this mode only if the rotating ID run is
not possible (the motor cannot be de-coupled from
the elevator system).
1
ID adv st
Advanced standstill ID run.
2
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...