106 Using the control panel
Editing changed parameters
Step Action
Display
1.
Go to the Main menu by pressing
if you are
in the Output mode, otherwise by pressing
repeatedly until you get to the Main menu.
2.
Go to the Changed Parameters mode by selecting
CHANGED PAR on the menu with keys
and
, and pressing
.
If there are no changed parameters in the history,
corresponding text will be shown.
3.
If parameters are changed, a list of them is shown.
Select the changed parameter on the list with keys
and
. The value of the selected
parameter is shown below it.
4.
Press
to modify the value.
5.
Specify a new value for the parameter with keys
and
.
Pressing the key once increments or decrements
the value. Holding the key down changes the value
faster. Pressing the keys simultaneously replaces
the displayed value with the default value.
To accept the new value, press
. If the new
value is the default value, the parameter is
removed from the list of changed parameters.
To cancel the new value and keep the original,
press .
MENU
EXIT
PARAMETERS
ASSISTANTS
CHANGED PAR
EXIT
ENTER
00:00
MAIN MENU
1
LOC
ENTER
00:00
No parameters
MESSAGE
LOC
9903 Mot nom current
3.5 A
9904 Mot nom voltage
9905 Mot nom freq
9906 Mot nom speed
CHANGED PAR
EXIT
EDIT
00:00
LOC
EDIT
9903 Mot nom current
PAR EDIT
3.5
A
CANCEL
SAVE
00:00
LOC
9903 Mot nom current
PAR EDIT
3.0
A
CANCEL
SAVE
00:00
LOC
SAVE
CANCEL
9903 Mot nom current
3.0 A
9904 Mot nom voltage
9905 Mot nom freq
9906 Mot nom speed
CHANGED PAR
EXIT
EDIT
00:00
LOC
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...