Parameters 257
58.03
NODE ADDRESS
Defines the node address.
1 /
0…247
Node address.
1 = 1
58.04
BAUD RATE
Selects the baud rate of the RS-485 link.
9600 /
4800
4.8 kbit/s.
0
9600
9.6 kbit/s.
1
19200
19.2 kbit/s.
2
38400
38.4 kbit/s.
3
57600
57.6 kbit/s.
4
76800
76.8 kbit/s.
5
115200
115.2 kbit/s.
6
58.05
PARITY
Selects the number of the data bits, the use and type
of the parity bit, and the number of the stop bits.
8 NONE 1 /
8 NONE 1
Eight data bits, no parity bit, one stop bit.
0
8 NONE 2
Eight data bits, no parity bit, two stop bits.
1
8 EVEN 1
Eight data bits, even parity bit, one stop bit.
2
8 ODD 1
Eight data bits, odd parity bit, one stop bit.
3
58.06
CONTROL
PROFILE
Selects the communication profile used by the
Modbus protocol.
ABB
ENHANCED
/
ABB CLASSIC
ABB Drives profile, classic version.
0
ABB ENHANCED ABB Drives profile, enhanced version.
1
DCU 16-BIT
DCU 16-bit profile.
2
DCU 32-BIT
DCU 32-bit profile.
3
58.07
COMM LOSS T
OUT
Defines the timeout limit for EFB communication loss
monitoring.
If a communication break exceeds the timeout limit,
the function proceeds with the action defined with
parameter
COMM LOSS ACTION
. See also
parameter
COMM LOSS MODE.
600 ms /
0…60000 ms
Timeout calculation factor. The actual timeout value
is calculated as follows:
Comm loss timeout × 100 ms
Example:
If you set this value to 22, the actual
timeout value will be: 22 × 100 ms = 2 200 ms.
100 = 1 ms
58.08
COMM LOSS
MODE
Enables/disables EFB communication loss
monitoring and defines which of the Modbus register
accesses resets the timeout counter. See parameter
COMM LOSS T OUT.
NONE /
NONE
EFB communication loss monitoring is disabled.
0
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...