156 Program features
When the mechanical brake is closed and the drive stopped, that is, brake control is
active, the drive generates alarm BRAKE SLIP if the difference of the motor actual
speed and the speed reference is greater than the value of parameter
STD DEV LVL for a period longer than defined with parameter
SPEED MATCH
DLY.
The figure below illustrates the operation of the Speed match function.
Settings
Diagnostics
Parameters
Additional information
SPEED MATCH
Enables/disables the Speed match function.
Defines the speed matching steady state deviation.
Defines the speed matching ramp state deviation.
SPEED MATCH DLY
Defines the time delay for generating fault SPEED MATCH.
Signals
Additional information
Actual signals
LIFT SW bit 11
(BRAKE SLIP)
Displays whether alarm BRAKE SLIP has occurred or not.
LIFT FW bit 0
(SPEED MATCH)
Displays whether fault SPEED MATCH has occurred or not.
Motor actual speed (01.01 Speed act)
81.06 Speed match dly (0.5 s)
81.06 Speed match dly (0.5 s)
81.04 Spd std dev lvl (±0.5 m/s)
Ramped speed reference (03.04 Speedref ramped)
81.05 Spd rmp dev lvl (±0.6 m/s)
81.04 Spd std dev lvl (±0.5 m/s)
Time
Speed (m/s)
Time
SPD RMP DEV LVL (
±
0.6 m/s)
±
0.5 m/s)
SPEED MATCH DLY (0.5
s)
(0.5 s)
Motor actual speed (
SPEED ACT)
Ramped speed reference (
SPEEDREF ACT)
Speed (m/s)
SPD STD DEV LVL
(
±
0.5 m/s)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...