Program features 147
Smart slowdown
The Smart slowdown function optimizes the travel time of the elevator by reducing
the leveling path. That is, transition from the traveling speed (ie, nominal speed,
medium speed, speed2 or speed 3) to the leveling speed is optimally delayed based
on the knowledge of the physical leveling distance (ie, the distance between the
leveling and stop switches).
The function is useful in operation situations where the desired traveling speed is not
reached before the leveling command is activated (for example, in case of short floor
distance). If the leveling command is activated while the drive is still accelerating, the
achieved speed is maintained and no further acceleration is done.
The figure below illustrates the operation of the function.
Safety distance = Distance traveled with the leveling speed (parameter
SAFETY MARGIN defines what percentage of parameter
LV STOP SWC DIST
is used as the safety distance.)
You can enable the Smart slowdown function with estimated speed or with an
encoder using parameter
SMART SLOWDN SEL.
• When the function is enabled with estimated speed, it measures the distance
traveled by integrating the actual speed (m/s) in meters.
• When the function is enabled with an encoder, it uses actual signal
ACT to measure the distance traveled.
83.02 LV STOP SWC DIST
Stop
switch
Leveling
switch
Speed (m/s)
Distance (m)
Smart slowdown
enabled
Smart slowdown
disabled
Safety
distance
Distance (m)
Speed (m/s)
Smart slowdown
enabled
Smart slowdown
disabled
LV STOP SWC DIST
Stop switch
Leveling
switch
Safety distance
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...