Parameters 245
46
46 FAULT
FUNCTIONS
Settings for drive behaviour upon a fault situation. An
alarm or a fault message indicates abnormal drive
status.
This parameter group also includes settings for
thermal protection of the motor. See also section
.
46.01
EXTERNAL FAULT
Selects an interface for an external fault signal.
0 = External fault trip. 1 = No external fault.
C.True/
Bit pointer: CONST or POINTER (See
on page
.)
1 = 1 / -
46.02
MOT PHASE LOSS
Selects how the drive reacts when a motor phase
loss is detected.
Fault /
No
No action.
0
Fault
Drive trips on MOTOR PHASE fault.
1
46.03
EARTH FAULT
Selects how the drive reacts when an earth fault or
current unbalance is detected in the motor or the
motor cable.
Fault /
No
No action.
0
Warning
Drive generates alarm EARTH FAULT.
1
Fault
Drive trips on EARTH FAULT.
2
46.04
SUPPL PHS LOSS
Selects how the drive reacts when a supply phase
loss is detected.
Fault /
No
No reaction.
0
Fault
Drive trips on SUPPLY PHASE fault.
1
Warning
Drive generates alarm SUPPL PHS LOSS.
2
46.05
STO DIAGNOSTIC
Selects how the drive reacts when it detects the
absence of one or both Safe torque off (STO)
signals.
Note:
This parameter is for supervision only. The
Safe torque off function can activate even when this
parameter is set to NO.
For general information on the Safe torque off
function, see the
Hardware manual
of the drive.
Fault
The drive trips on SAFE TORQUE OFF when one or
both of the Safe torque off signals are lost.
1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...