Parameters 225
AI2 max tune
Current analogue input AI1 signal value is set as
maximum value for AI1, parameter
AI1 MAX.
The value reverts back to
automatically.
2
AI2 min tune
Current analogue input AI2 signal value is set as
minimum value for AI2, parameter
AI2 MIN.
The value reverts back to
automatically.
3
AI2 max tune
Current analogue input AI2 signal value is set as
maximum value for AI2, parameter
AI2 MAX.
The value reverts back to
automatically.
4
13.12
AI SUPERVISION
Selects how the drive reacts when analogue input
signal limit is reached. The limit is selected by
parameter
AI SUPERVIS ACT
.
No
No action taken.
0
Fault
The drive trips on fault AI SUPERVISION.
1
Spd ref safe
The drive generates alarm AI SUPERVISION and
sets the speed.
WARNING!
In case of a communication
break, make sure that it is safe to continue
operation.
2
Last speed
The drive generates alarm AI SUPERVISION and
freezes the speed to the level the drive was
operating at. The speed is determined by the
average speed over the previous 10 seconds.
WARNING!
In case of a communication
break, make sure that it is safe to continue
operation.
3
13.13
AI SUPERVIS ACT
Selects the analogue input signal supervision limit.
0b0000 /
Example: If the parameter value is set to 0010 (bin),
bit 1 AI1>max is selected.
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Supervision selected by parameter
AI
SUPERVISION is activated if
0
AI1<min
AI1 signal value falls below the value defined by equation:
par.
AI1 MIN - 0.5 mA or V
1
AI1>max
AI1 signal value exceeds the value defined by equation: par.
AI1 MAX + 0.5 mA or V
2
AI2<min
AI2 signal value falls below the value defined by equation:
par.
AI2 MIN - 0.5 mA or V
3
AI2>min
AI1 signal value exceeds the value defined by equation: par.
AI2 MAX + 0.5 mA or V
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...